— 28 —
A-8. Plug 10 connectors and 1 FPC.
NOTE
: Do not tangle the wires.
A-9. Secure it with seven screws.
A-10. Connect the Touch Panel PCB (E830-TP) to the FPC.
Screws (S9)
Screws (S9)
NOTE
: Position it so that the earth terminal
is in the correct orientation.
Screws (S9)
A-12. Engage the Mic PCB (E830-MIC) and secure it with two screws.
A-13. Engage the MCR Unit.
Screws (S7)
Screws (S5)
A-11. Engage the Power Supply PCB (E830-INLET) and secure it with two screws.
NOTE
: Two Drawer Cables are arranged under the PCB.
Screws (S9)
Drawer cables
Summary of Contents for QT-6600
Page 1: ...SERVICE MANUAL QT 6600 ELECTRONIC CASH REGISTER QT 6600 EX 830 NOV 2008 Ver 5 Oct 2014 ...
Page 26: ... 23 M 13 Disengage and remove the LCD Unit LCD unit ...
Page 98: ... 95 10 PCB LAYOUT MAIN PCB E830 1 PCB TOP VIEW ...
Page 99: ... 96 MAIN PCB E830 1 PCB BOTTOM VIEW ...
Page 101: ... 98 INLET PCB E830 INLET PCB MIC PCB E830 MIC PCB LED PCB E830 E6 PCB TOP VIEW BOTTOM VIEW ...