18
PAD
Perform PAD related settings
SET – PAD – SETPAD
: Setting the No. of PAD
Prior to performing this setting, turn on the power for one of the PAD. Normal setting is
impossible if several PADs are turned on.
ID message will be displayed when
▲
key or
▼
key is pressed while Detailed
MenuSETPAD is displayed. Enter the desired number.
When LEVEL3 key is pressed and when No. of PAD is normally set, then message in the
format of “OK PAD Number” will be displayed.
When communication with PAD fails, ERROR message will be displayed.
After the setting, save and exit with LEVEL3 key.
SET – PAD – CHKPAD:
Verification of No. of connected PAD
Prior to performing this checking, turn on the power for one of the PAD. Normal checking is
impossible if several PADs are turned on.
When
▲
key or
▼
key is pressed while Detailed MenuCHKPAD is displayed, the No. of
PAD of the PAD for which the power is turned on at the moment will be displayed.
After having confirmed the PAD No., exit by pressing the LEVEL3 key. When
communication with PAD fails, NONE message will be displayed.
SET – PAD – PADNUM
: Setting No. of PAD to be used
Set the number of PADs to be used by using the
▲
key and
▼
key while Detailed
MenuPADNUM is displayed. Save the setting and exit with LEVEL3 key.
This product can measure the weight of the truck with 2 modes, namely, the
static weighing mode that measures the weight after having stopped the
wheel axle of the truck on the PAD, and the dynamic weighing mode that
measures the weight while passing the PAD at low speed.
In the case of dynamic weighing mode, accurate weight may not be indicated
depending on the speed of the vehicle and the given environment.
Number of PADs that can be connected when using the dynamic weighing
mode is 2.
You must set the number of PAD to 2 in the SET – PAD – PADNUM mode.