OWNER’S MANUAL
SYSTEM OPERATING INFORMATION
96
7
3237 • X6 02/2018
OTEE:
N
If the Receptacles ONE circuit breaker
is ON, but power is not available to the
receptacles in this group, the circuit’s
GFCI breaker may have tripped. Refer
to Ground Fault Circuit Interrupters
later in this section for more
information.
Receptacles Two
The RECEPTACLES TWO breaker controls the flow of
electricity to the receptacles in the salon and dinette. The
receptacles are used the same as in-home outlets.
OTEE:
N
If the Receptacles TWO circuit breaker
is ON, but power is not available to the
receptacles in this group, the circuit’s
GFCI breaker may have tripped. Refer
to Ground Fault Circuit Interrupters
later in this section for more
information.
Thruster Battery Charger (Option)
The THRUSTER BATT CHARGER breaker controls the
flow of electricity to the bow/stern thruster and generator
battery charger that maintains the voltage levels in the
battery supplying power to the bow and/or stern thruster.
Refer to the OEM information for details on operating the
battery charger.
Water Heater
The WATER HEATER breaker controls the power to the
water heater located in the engine room. Refer to the
OEM information for details on operating the water heater.
DO NOT supply power to the water heater when the water
heater is empty.
NOTICE
Line 2/Shore 2 Circuit Breakers
A/C Water Pump
The A/C WATER PUMP breaker controls the flow
of electricity to the water pump that supplies the air
conditioning system with seawater.
Do not switch the Air Conditioning System Water Pump
breaker ON until after the seacock supplying the air
conditioning system with seawater has been opened. Refer
to Air Conditioning System for more information.
NOTICE
A/C Unit Fwd S/R
The A/C UNIT FWD S/R breaker controls the flow of
electricity to the air conditioning unit that cools the Master
Stateroom, Guess Stateroom, and Head. To supply
power to the unit, switch the A/C System Water Pump
breaker ON, before switching the Air Conditioning Unit
Master Stateroom breaker ON.
Do not switch the Air Conditioning unit master stateroom
breaker ON until after the seacock supplying the air
conditioning system with seawater has been opened.
NOTICE
AC Unit Salon (2 Breakers)
The AC UNIT SALON breaker controls the flow of
electricity to the air conditioning unit that cools the Salon
and Galley. To supply power to the unit, switch the A/C
System Water Pump breaker ON, before switching the Air
Conditioning Unit Salon breaker ON.
C34_Coupe.indb 96