OWNER’S MANUAL
SYSTEM OPERATING INFORMATION
92
7
3237 • X6 02/2018
Bilge Blower
Switch
Generator
Start/Stop
Switch
Bilge Blower 1 – 4
Circuit Breakers
Figure 7-16
The starter can be damaged by holding down the
generator switch in the START position after the generator
is started. The generator START/STOP switch is spring-
activated. Release the switch from the START position
once the generator begins to crank. Never hold the STOP/
START switch in the START position for more than 2
seconds.
NOTICE
4 ]
On the DC control center, press and hold the
GENERATOR START/STOP switch until the
generator begins to crank. The generator cranking/
starting cycle is automatic after the initial press/
hold and release of the GENERATOR START/STOP
switch. The generator will crank for 10 seconds and
automatically stop cranking if the generator does
not start. A second start cycle can be attempted
after the first stop. If the generator does not start
after two attempts, consult the generator owner’s
manual troubleshooting guide. Stopping the
generator also only requires a momentary press
and hold of the GENERATOR START/STOP switch.
5 ]
Once the generator is running smoothly, switch the
GENERATOR circuit breaker group ON, located on
the AC control center. The breaker group connects
the AC electrical system to the generator output.
Once the GENERATOR RUNNING indicator light
illuminates, power is available to the other circuit
breakers on the AC control center.