Command Format
11
Report Description
The Get Configuration Report details the configuration of the touch
system.
Report Format
11 ComponentCount
ComponentType
AttributeCount
AttributeTag AttributeValue
AttributeTag AttributeValue...
ComponentType...FF
ComponentCount
=
Number of components in the touch system.
ComponentType
=
Type of component:
0
=
Unknown. The component exists and has
attributes, but its type could not be determined.
1
=
Sensor/frame. This is the touch sensing portion of
the touch system, such as a GW sensor or IR
frame.
2
=
Controller. This is the portion of the touch system
that controls one or more touch sensing portions
of the touch system.
3
=
Processor. This is the portion of the touch system
that executes the operating firmware.
No ComponentType value is defined for Smart-Frames;
Smart-Frames are treated as the combination of a
sensor/frame and a controller.
AttributeCount
=
Number of attribute tag/value pairs in the component.
AttributeTag
=
Indicates the meaning of the attribute. Values for
AttributeTag depend upon the value of ComponentType.
Refer to Table B-3 for the possible values.
Summary of Contents for TouchSystems CarrollTouch Prog
Page 1: ...CARROLL TOUCH TOUCH PRODUCTS an company AMP Touch System Programmer s Guide ...
Page 11: ...Table of Contents CARROLL TOUCH viii ...
Page 13: ...Table of Contents CARROLL TOUCH x ...
Page 17: ...Welcome CARROLL TOUCH xiv Touch System Programmer s Guide ...
Page 41: ...Chapter 3 General Programming Issues CARROLL TOUCH 3 12 Touch System Programmer s Guide ...
Page 57: ...Chapter 4 Smart Frame Protocol CARROLL TOUCH 4 16 Touch System Programmer s Guide ...
Page 237: ...Appendix D CTKERN Function Reference CARROLL TOUCH D 42 Touch System Programmer s Guide ...