Run_Diagnostics (3AH) (:)
Command Description
When the host sends the Run_Diagnostics (3AH) command, the touch
system executes all of the diagnostics tests that occur at power-up (such
as the RAM test, ROM test, and so forth) and generates an Error Report.
The touch system then resets the system defaults, just as if the power
had been turned off and then on again. The performance of these
diagnostics routines may take up to one second to complete.
Since the touch system defaults are reset, the host must send either the
Report_Transfer_On (44H) command or the Get_One_Report (46H)
command to the touch system so that the host can receive the Error
Report.
Report Format
See Get_Error_Report (32H) in this appendix for details of the Error
Report.
See Also
Get_Error_Report (32H)
Software_Reset (3CH)