CARROLL TOUCH
Chapter 4 - Smart-Frame Protocol
Touch System Programmer’s Guide
4-5
Changing the touch mode clears the Add Exit Point modifier. To
disable the Add Exit Point modifier without changing the current touch
mode, simply send the desired touch mode command again.
For example, to select Tracking Mode with Add Exit Point, send the
Tracking_Mode (26H) command followed by the
Add_Exit_Point_Modifier (29H) command. To deselect Add Exit Point
and remain in Tracking Mode, send the Tracking_Mode (26H)
command again.
Information Request Commands
Information request commands query the touch system for system
status reports, such as error, configuration, firmware version, failed
beam, frame size, and state reports. Information request commands are
shown in Table 4-4.
System Commands
System commands control all touch system functions such as
initialization, software reset, diagnostics, and scanning. The system
commands are shown in Table 4-5.
Table 4-4. SFP Information Request Commands
Command Name
Hex
Code
ASCII
Code
Associated
Report
Get_Error_Report
32H
2
Error Report
Get_Configuration_Report
33H
3
Configuration Report
Get_Firmware_Version_
Report
34H
4
Firmware Version
Report
Get_Failed_Beam_Report
36H
6
Failed Beam Report
Get_Frame_Size_Report
37H
7
Frame Size Report
Get_State_Report
47H
G
State Report
Summary of Contents for TouchSystems CarrollTouch Prog
Page 1: ...CARROLL TOUCH TOUCH PRODUCTS an company AMP Touch System Programmer s Guide ...
Page 11: ...Table of Contents CARROLL TOUCH viii ...
Page 13: ...Table of Contents CARROLL TOUCH x ...
Page 17: ...Welcome CARROLL TOUCH xiv Touch System Programmer s Guide ...
Page 41: ...Chapter 3 General Programming Issues CARROLL TOUCH 3 12 Touch System Programmer s Guide ...
Page 57: ...Chapter 4 Smart Frame Protocol CARROLL TOUCH 4 16 Touch System Programmer s Guide ...
Page 237: ...Appendix D CTKERN Function Reference CARROLL TOUCH D 42 Touch System Programmer s Guide ...