Hardware_Flow_Control_Off (42H) (B)
Command Description
When the host sends the Hardware_Flow_Control_Off (42H)
command, the touch system stops using hardware handshaking to
regulate serial communication with the host.
Data Terminal Ready (
DTR
) is ignored by the touch system, and
Smart-Frame Protocol reports are always transmitted.
For touch systems that use the modular RS-232 controller, Clear To
Send (
CTS
) is always asserted, indicating that the touch system is ready
to receive commands (even when it is not).
For Smart-Frame type touch systems,
CTS
follows the state of Request
To Send (
RTS
) signal from the host and is asserted if
RTS
is asserted
and deasserted if RTS is deasserted.