Install the atomizing head 

on the float assembly.

Put the main unit on the table, 

and align the mist guiding tube 

with slot of it for installation.

Install the float assembly into 

the mist tube.(The upper shell of  

the float faces the direction of the

 main unit.)

Rotate the lower cover of 

the tube clockwise.

Connect the atomizing head

 hose to the main unit.

NOTICE

Mist tube assembly installation

  Page 11  

The foam of the float in Fig 7  is important part of atomizing head assembly,

DO NOT

 mistakenly discard it as part of the packaging.

Summary of Contents for ME-F800W

Page 1: ...产品中限制使用有害物质的技术标准 会 签 制 图 设 计 校 对 审 核 标准化 审 定 日 期 标记 处数 更改文件号 签 字 日 期 加湿器 说明书 重点 校对项 1 版面尺寸 2 材质标注 3 物料编码 4 颜色标注 5 客户型号 6 产品名称 7 重量标注 8 电压功率 9 说明书装 订要求 10 警语 认证 标志高度 11 档位 控制面板 一致性 1 备注 70P以下为钉装 70P以上为胶装 特殊要求除外 Ultrasonic Humidifier USER MANUAL Model ME F800W Warning Notice Before using this product please read this manual carefully and keep it for future reference The design and specifications are...

Page 2: ...is product please read this manual carefully and keep it for future reference The design and specifications are subject to change without prior notice for product improvement Consult with your dealer or the manufacturer for details Rated voltage 120V Rated power 24W Frequency 60Hz ...

Page 3: ...different levels of risk is shown by the following indications CAUTION This symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury This symbol addresses practices not related to physical injury NOTICE This symbol indicates a hazardous situation which if not avoided could result in death or serious injury WARNING READ AND SAVE THESE INSTRUCTIONS IMPORTA...

Page 4: ...lease use purified water for humidification Please do not use a damaged or worn power cord Do not replace the power cord without authorization If the power cord is damaged it must be replaced by the manufacturer its service department or professional from similar department to avoid danger The power must be cut off in thunderstorm When an abnormal phenomenon like a burnt smell occurs the operation...

Page 5: ...than the highest water level Please be not to add the water in the atomization outlet when the water is added Please do not add additives like essential oil perfume drug etc to the water Please use the purified water below 104 F Do not use distilled water NOTICE The following are the design parameters of ME F800W the measured parameters are subject to the product The humidification amount will var...

Page 6: ...ly and the actual product in the packing box shall prevail The product appearance and function vary with the model Please be subject to the real product with optional reading of the respective function description Water Mist Guiding Tube Water Tank Main Unit Control Panel Atomization Outlet ...

Page 7: ...rectly through the main unit cover Please use purified water Please do not add the water in the atomization outlet Method B Lift the main unit of the humidifier up and fill purified water directly from top of the water tank 1 Atomization Outlet Main Unit Cover Purified Water Purified Water ...

Page 8: ...etting the setting timer time will be displayed first and then if you do not operate the timer will flash 3 times and then switch to display the humidity of the current environment 3 The timer time displays in a countdown way After setting the timer if you press the timer button again the operation screen will display the remaining time before shutdown and then press the timer button again to re s...

Page 9: ...60 Page 8 CLEANING AND MAINTENANCE WARNING Before cleaning or descaling be sure to unplug the power cord Do not use abrasive corrosive or flammable cleaners such as bleach or alcohol to clean any part of the humidifier The humidifier must regularly clean the scale and debris in the water tank and sink It is recommended to clean it once a week Water shortage indicator light IMPORTANT TIP DO NOT lea...

Page 10: ...eaning First take out the main unit cover then lift the main unit upwards shake the main unit slightly so that the water in the mist guiding tube flows back to the water tank put the main unit aside then pour clean water into the water tank and add an appropriate amount of detergent for cleaning Use a clean cloth to dry the inside and outside of the water tank Warning Do not use a dripping soft cl...

Page 11: ...sembly as shown in Fig 4 4 Clean the dirt inside the tube with a long handled soft brush as shown in Fig 5 and then wash the tube in the sink 5 Use a screwdriver to poke the small hole in the back of atomizing head assembly and take out the atomizing head for cleaning as shown in Fig 6 and wipe the center of it with a damp soft cloth 6 When cleaning the components of the float first rotate the upp...

Page 12: ...assembly into the mist tube The upper shell of the float faces the direction of the main unit Rotate the lower cover of the tube clockwise Connect the atomizing head hose to the main unit NOTICE Mist tube assembly installation Page 11 The foam of the float in Fig 7 is important part of atomizing head assembly DO NOT mistakenly discard it as part of the packaging ...

Page 13: ...pp and working normally b Open Alexa app go to the skill to search Carro Home skill c Link the skill log in with your Carro Home app account and password then authorize and connect with Carro Home app d Then the Alexa will find out the device automatically 5 Connect the device to the Google Home a Make sure you have connected the device to the app and working normally b Open Google Home app Set up...

Page 14: ...ew machine Leave the water tank open in the shade for 12 hours Use of tap water with a high mineral content aka hard water The appliance is not in place tilted or unstable Excessive tilting of the appliance at an angle causes the water level in the water tank to be judged as low water level so the appliance automatically starts protection mode and stops The water tank is short of water The power p...

Page 15: ... and does not cover Wear and tear Stains Misuse or improper maintenance Alteration or repair by unauthorized representatives Damage resulting from transit or handling Damage caused by improper placement such as placing products near he ating pipes etc Deterioration caused by Force Majeure unforeseeable circumstances such as fire earthquake flood lightning and other natural disasters environmen tal...

Page 16: ...ar installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on ...