background image

Tel: 1-888-641-8862

Web: www.baseaire.com  

E-mail: [email protected]

Installation

 & 

Operations

 

Manual

AirWerx 140X

Patent pending

Specifications subject to change without notice.

Summary of Contents for AirWerx 140X

Page 1: ...Tel 1 888 641 8862 Web www baseaire com E mail sales baseaire com Installation Operations Manual AirWerx 140X Patent pending Specifications subject to change without notice ...

Page 2: ......

Page 3: ...stration Specifications How it Works Installation Key Functions Indicator Lights Remote Control Operating Instructions Unit Diagram Maintenance Dehumidifier Storage Troubleshooting Spare Parts Warranty Information 2 2 3 3 3 4 5 6 7 8 9 11 12 13 14 1 ...

Page 4: ...nsert objects or your fingers into the inlet or discharge Do not use water to clean the exterior of the dehumidifier To clean unit unplug from power then use a damp cloth to wipe the exterior Do not stand on dehumidifier or place objects on it Do not use with extension cord or plug adapter Unless otherwise noted all maintenance should be done with the unit powered off The unit must be used in the ...

Page 5: ...ier will energize Air is then drawn across an evaporator coil which is cooler than the dew point of air This means moisture will condense out of the air The air is then reheated through the condenser coil and distributed back into the room Do not place unit directly on vapor barrier For example use blocks or pavers to create a level surface If unit has been turned or flipped so that the compressor...

Page 6: ...un continuously regardless of humidity simply use the down arrow key to set the humidity below 35 4 Key Functions The continuous light will illuminate green and the display will show CO To switch back to normal humidistat operation use the arrow keys to move the setpoint above 35 4 Manual Drain Button If you need to store or move your dehumidifier press the Drain button to remove water from the in...

Page 7: ...y is above the setpoint the light will be solid green and the machine will operate If the humidity is below the setpoint the unit will be in standby mode and the light will be flashing 3 Continuous Mode Auto Defrost Light When the light illuminates green it indicates that the dehumidifier is set to continuous operation mode When the light illuminates red it means the unit is in auto defrost mode a...

Page 8: ...on Press the on off button and the machine will start running two beeps Press the button again to turn the machine off 2 Up Button Down Button Use the up and down arrows to adjust the humidity level 3 Mode Use the mode button to switch between dehumidifier and a ducted application The symbol on the display indicates the sensor on the remote control is being utilized The symbol on the display indic...

Page 9: ...ess the power button again and the dehumidifier will stop Note that the fan will continue to operate for 1 minute after the unit has shut off The AirWerx 140X has an integrated condensate pump During normal operation the 140X will automatically drain as required If you would like to store or move your unit press the drain button to drain water from the pump reservoir The drain will operate for 15 ...

Page 10: ...8 Unit Diagram Front View Back View Side Panel Remote Control Control Panel Pre filter Drain Hose Connection Power Cord ...

Page 11: ...in The pump requires routine maintenance that is not covered by the warranty Preventative maintenance is necessary to prevent issues from dirt and slime that may accumulate in the drain system This includes the drain pan hose to the condensate pump pump reservoir pump head assembly and discharge tubing Coil Maintenance Once per year clean the coils with an approved coil cleaner The coil cleaner sh...

Page 12: ...um or towels can be used to remove any remaining water 2 Unplug the dehumidifier and remove the cover so you have access to the pump 3 Remove the pump head from the reservoir by unscrewing the screw Wipe reservoir clean with a paper towel 4 Reassemble pump 5 Mix a 16 ounce solution of bleach 1 oz bleach 15 oz water OR vinegar 4 oz white vinegar 12 oz water 6 Pour the cleaning solution into the dra...

Page 13: ...tended period of time complete the following steps 1 Turn off the unit and allow it to dry 2 Complete steps 1 3 in Advanced Pump Cleaning to clean out the pump reservoir 3 Wrap and secure the power cord 4 Cover the filter mesh 5 Store in a clean dry space 11 ...

Page 14: ...ify that both ends of the power cord are plugged in Power Outage Reset power Trouble Code LO Clean the filter Clear the blockage Filter is Dirty Air Inlet or Outlet is Blocked Diaplay is Blank No AirFlow Trouble Code E4 Trouble Code E1 Problem with Pump Room Temperature is below 33 8 Humidity Sensor or Communication Error Check to ensure that the sensor wire is connected at both ends if no issues ...

Page 15: ...y Board N 102 AirWerx RH Temp Sensor Internal Components N 801 N 118 Compressor Compressor Capacitor N 800 Coil Assembly N 119 Hot Gas Valve Assembly N 803 Condensate Pump Assembly Filters External Components N 200 N 201 AirWerx Prefilter AirWerx MERV 10 N 202 AirWerx HEPA N 203 Carbon Filter N 125 Foot adjustable Cables N 102 N 121 Temp RH Sensor Cable Display Ribbon Cable N 122 CAT 5 Port Intern...

Page 16: ...mer is responsible for all risk of loss or damage BaseAire Warranty Steps 1 Once receive the goods customers must log in www baseaire com to fill out the warranty Registration form and submit to BaseAire company We will receive your purchasing and installation information and save it If no warranty registration is sent to us warranty period will begin the day the shipment left the warehouse Please...

Page 17: ...RANTIES AND LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED IN LAW OR IN FACT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE BaseAire s total liability regardless of nature of claim shall not exceed original purchase exceed original purchase price of the product if a product or component is replaced while under warranty the applica...

Page 18: ......

Page 19: ......

Page 20: ...Scan QR Code to Register Warranty ...

Reviews: