8
ARI* CAPACITY RATINGS — 50HJQ004-006
ARI* CAPACITY RATINGS — 50HJQ007-012
LEGEND
*Air Conditioning and Refrigeration Institute.
†Applies only to units with capacity of 60,000 Btuh or less.
NOTE: Rated in accordance with ARI Standard 210/240-94 and 270-95. Ratings
are net values, reflecting effects of circulating fan heat. Supplementary electric
heat is not included. Ratings based on:
Cooling Standard:
80 F db (dry bulb), 67 F wb (wet bulb) indoor entering-air tem-
perature and 95 F db outdoor entering-air temperature.
IPLV Standard:
80 F db, 67 F wb indoor entering-air temperature and 80 F db out-
door entering-air temperature.
High-Temp Heating Standard:
70 F db indoor entering-air temperature and 47 F
db, 43 F wb outdoor entering-air temperature.
Low-Temp Heating Standard:
70 F db indoor entering-air temperature and 17 F
db, 15 F wb outdoor entering-air temperature.
ALL the 50HJQ and 50TFQ004,005 and 006 units are in compliance
with ASHRAE 90.1 2001 Energy Standard for minimum SEER and EER require-
ments. Refer to state and local codes or visit the following website:
http://solstice.crest.org/efficiency/bcap to determine if compliance with this
standard pertains to a given geographical area of the United States.
ARI* CAPACITY RATINGS —50HJQ014,016 UNITS
LEGEND
*Air-Conditioning and Refrigeration Institute.
NOTE: 50HJQ units are rated in accordance with ARI Standard 340-93.
Cooling ratings are net values, reflecting the effects of circulating fan
heat. Ratings are based on:
ESP: –.35 in. wg
Cooling Standard:
80 F db, 67 wb indoor coil entering-air temperature
and 95 F outdoor entering-air temperature.
High-Temp Heating Standard:
70 F db indoor coil entering-air temper-
ature and 47 F db, 43 F wb outdoor coil entering-air temperature.
Low-Temp Heating Standard:
70 F db indoor coil entering-air temper-
ature and 17 F db, 15 F wb outdoor coil entering-air temperature.
IPLV Standard:
80 F db, 67 F wb indoor entering-air temperature and
80 F db outdoor entering-air temperature.
ALL the 50HJQ and 50TFQ004,005 and 006 units are in compliance
with ASHRAE 90.1 2001 Energy Standard for minimum SEER and EER
requirements. Refer to state and local codes or visit the following web-
site: http://solstice.crest.org/efficiency/bcap to determine if compliance
with this standard pertains to a given geographical area of the United
States.
UNIT
50HJQ
NOMINAL
TONS
COOLING
HEATING (High Temp)
SOUND
RATING
(decibels)
Net Cap.
(Btuh)
SEER†
Cap.
(Btuh)
HSPF†
004
3
35,600
13.1
34,800
7.7
76
005
4
45,000
13.0
45,000
7.8
76
006
5
58,000
13.0
55,000
7.7
80
UNIT
50HJQ
NOMINAL
TONS
COOLING
HEATING
(High)
HEATING
(Low)
SOUND
RATING
(decibels)
IPLV
Net Cap.
(Btuh)
EER
Cap.
(Btuh)
COP
Cap.
(Btuh)
COP
007
6
71,000
10.5
69,000
3.4
37,000
2.2
80
—
008
7
1
/
2
88,000
10.3
85,000
3.3
48,000
2.2
82
10.5
009
8
1
/
2
98,000
10.3
96,000
3.3
52,000
2.2
110
12.7 (100%)
10.4 ( 50%)
012
10
116,000
10.3
114,000
3.3
64,000
2.2
84
10.4
Cap.
—
Net Capacity (Btuh)
COP
—
Coefficient of Performance
EER
—
Energy Efficiency Ratio
HSPF
—
Heating Seasonal Performance Factor
IPLV
—
Integrated Part-Load Values
SEER
—
Seasonal Energy Efficiency Ratio
UNIT
50HJQ
COOLING
HEATING-HIGH TEMP
HEATING-LOW TEMP
SOUND
RATING
(decibels)
Total
kW
Net
Capacity
(Btuh)
Cfm
IPLV
EER
Total
Capacity
(Btuh)
Total
kW
COP
Total
Capacity
(Btuh)
Total
kW
COP
014
14.3
140,000
4500
12.4
9.8
136,000
12.4
3.2
72,000
10.0
2.1
87
016
18.5
172,000
5200
9.7
9.3
172,000
15.3
3.3
90,000
12.5
2.2
88
COP
—
Coefficient of Performance
db
—
Dry Bulb
EER
—
Energy Efficiency Ratio
ESP
—
External Static Pressure
IPLV
—
Integrated Part-Load Value
wb
—
Wet Bulb
ARI* capacity ratings (cont)
Summary of Contents for WEATHERMASTER 50HJQ016
Page 19: ...19 Base unit dimensions 50TFQ004 007 50TFQ ...
Page 20: ...20 Base unit dimensions 50TFQ008 012 50TFQ ...
Page 84: ...84 Base unit dimensions 50HJQ004 007 50HJQ ...
Page 85: ...85 Base unit dimensions 50HJQ008 012 50HJQ ...
Page 141: ...141 Typical wiring schematics 50HJQ 50HJQ016 460 v shown 50HJQ ...