11

.22"

.17"

3.25

0.5"

0.5"

.53"

1.125"

FRONT VIEW

0.875"

1.09

1.45"

SIDE VIEW

GERMICIDAL LAMP

TO POWER
SUPPLY

Z-FLANGE

DOOR INTERLOCK
SWITCH

RAIN PROOF
LIGHT SWITCH
DISCONNECT

1.75"

Fig. 14 — Disconnect Wiring Hole Location 

(48/50HJ,TJ004-007 and 50HJQ004-007 Units Only)

Fig. 15 — Typical Germicidal Lamp Installation — 

48/50HJ,TJ008-014 and 

50HJQ008-012 Units Shown

Fig. 16 — Disconnect Switch Wiring Hole Location 

(48/50HJ,TJ008-014 and 50HJQ008-012 Units Only)

NOTE: Dimensions are in inches.

NOTES: 
1. Use 18 gage galvanized steel.
2. Dimensions are in inches.

Fig. 17 — Field-Fabricated Door 

Interlock Switch Bracket Details

(48/50HJ,TJ004-014 and 50HJQ004-012 Units Only)

Fig. 18 — Interlock Switch Installation

(48/50HJ,TJ004-014 and 50HJQ004-012 Units)

NOTE: Dimensions are in inches.

NOTE: Dimensions are in inches.

Summary of Contents for CRNEMAFX001A00

Page 1: ...s and microbial growth The Carrier germicidal lamps have been specifically de signed and optimized for 40 to 45 F high humidity operation in a moving airstream inside an HVAC unit The Carrier germi ci...

Page 2: ...le 1 Table 1 Wiring Recommendations 6 Any hinged potential access panel or door to the instal lation area must be interlocked with the accessory power source to turn the lamp off if the door is opened...

Page 3: ...e of part 2 On size 038 048 units use 4 bulbs spaced at 34 00 On size 054 068 units use 5 bulbs spaced at 34 00 3 Dimensions are in inches Fig 2 Germicidal Lamps Installation Location 48 50EJ EK EW EY...

Page 4: ...ll 1 in holes in unit where marked Fig 4 Germicidal Lamps Installation Location 48 50HJ TJ008 014 and 50HJQ008 012 Units NOTE Dimensions are in inches Fig 5 Accessory Dimensions NOTE Dimensions are in...

Page 5: ...an power source or any power source where they would be cycled more than twice per day NOTE If door interlock switch is used black power lead will be connected to the door interlock switch wir ing not...

Page 6: ...N 0 0 25 0 25 1 62 0 0 30 0 50 Fig 7 Disconnect Location 48 50HJ TJ015 028 Units and 50HJQ014 and 016 Units Fig 8 Field Fabricated Bracket for Door Interlock Switch 48 50HJ TJ015 028 Units and 50HJQ01...

Page 7: ...wired into the power Black lead between the disconnect switch and the junction box installed in Step 10 to break power to the accessory when the door is opened 7 Access doors may be equipped with a gl...

Page 8: ...ulb should glow with a blue hue If bulb cannot be seen briefly back out bulb and view from safe distance replace bulb when done If bulb does not glow check wiring safety interlock or replace bulb Inst...

Page 9: ...ll 0 406 in hole in unit z flange 1 75 in from end of door for pushbutton of interlock switch Push button will go through unit z flange and will be contacted by door See Fig 15 Use insulated sleeve te...

Page 10: ...season Bulb output can also be checked with a UVC radiometer Replace bulb when output falls to 70 of initial reading The following bulbs can safely be used with this accessory CRSGLTUB001A00 16 in tu...

Page 11: ...stallation 48 50HJ TJ008 014 and 50HJQ008 012 Units Shown Fig 16 Disconnect Switch Wiring Hole Location 48 50HJ TJ008 014 and 50HJQ008 012 Units Only NOTE Dimensions are in inches NOTES 1 Use 18 gage...

Page 12: ...change at any time specifications or designs without notice and without incurring obligations PC 111 Catalog No 534 734 Printed in U S A Form 48 50 51SI Pg 12 4 99 Replaces New Book 1 1 1 4 4 4 Tab 1a...