20
30XB-850 to 1700 standard units
30XB
850
900
1000
1100
1200
1300
1400
1500
1550
1700
Sound levels
Standard unit
Sound power
(1)
dB(A)
101
104
102
103
102
104
104
104
104
104
Sound pressure at 10 m
(2)
dB(A)
70
71
69
70
69
71
71
71
71
70
Unit + option 15
(3)
Sound power
(1)
dB(A)
97
99
98
98
98
100
99
99
100
100
Sound pressure at 10 m
(2)
dB(A)
65
66
65
65
65
67
65
65
67
66
Unit + option 15LS
(3)
Sound power
(1)
dB(A)
94
95
94
94
94
99
95
96
96
96
Sound pressure at 10 m
(2)
dB(A)
61
62
61
61
61
66
62
63
63
62
Unit + option 15LS+
(3)
Sound power
(1)
dB(A)
91
93
92
93
93
97
94
95
93
93
Sound pressure at 10 m
(2)
dB(A)
58
60
59
60
60
66
61
62
60
60
Dimensions
Standard unit
Length
mm
7186 7186 8380 9574 10770 11962 11962 13157 9574/
4798
8380/
8380
Width
mm
2253 2253 2253 2253 2253 2253 2253 2253 2253 2253
Height
mm
2322 2322 2322 2322 2322 2322 2322 2322 2322 2322
Operating weight
(4)
Standard unit
kg
5480 5749 6244 7202 7650 8545 8622 8928 3356/
6612
5835/
5835
Unit + option 15
(3)
kg
5765 6034 6521 7511 7952 8840 8917 9215 3557/
6985
6234/
6234
Unit + option 118A
(3)
kg
5868 6157 6643
-
-
-
-
-
-
-
Unit + option 50
(3)
kg
6294 6660 7144
-
-
-
-
-
-
-
Compressors
06T semi-hermetic screw compressor, 50 r/s
Circuit A
1
1
1
1
1
1
1
1
1
1
Circuit B
1
1
1
1
1
1
1
1
1
1
Circuit C
1
1
Circuit D
1
No. of control stages
Refrigerant for standard unit
(4)
R134a
Circuit A
kg
69
67
71
76
76
110
116
132
85
72
teqCO
2
98,7
95,8 100,8 108,7 108,7 157,3 165,9 188,8 121,6 103,0
Circuit B
kg
65
67
72
108
120
116
124
120
88
63
teqCO
2
93,0
95,8 103,0 154,4 171,6 165,9 177,3 171,6 125,8 90,1
Circuit C
kg
80
72
teqCO
2
114,4 103,0
Circuit D
kg
63
90,1
Oil
Circuit A
l
27,6
27,6
27,6
27,6
27,6
36,0
36,0
36,0
27,6
27,6
Circuit B
l
23,5
27,6
27,6
36,0
36,0
36,0
36,0
36,0
27,6
23,5
Circuit C
l
27,6
27,6
Circuit D
l
23,5
(1) in dB ref=10
-12
W, ‘A’ weighted. Declared dual-number noise emission values in accordance with ISO 4871 with an associated uncertainty of +/-3dB(A). Measured in
accordance with ISO 9614-1 and certified by Eurovent.
(2) In dB ref 20μPa, ‘A’ weighted. Declared dual-number noise emission values in accordance with ISO 4871 with an associated uncertainty of +/-3dB(A). For information,
calculated from the sound power Lw(A).
(3) Options : 15 = Low noise, 15LS = Very Low noise, 118a = DX freecooling option, 50= Heat recovery.
(4) Values are guidelines only. Refer to the unit name plate.
Eurovent certified values
4 - PHYSICAL AND ELECTRICAL DATA FOR 30XB UNITS