2. Floor Type Installation
When the unit is being installed on the floor,
refer to the following instructions:
CAUTION :
drain pipe leading-out direction shown with figure below.
Attention to distance from the unit to household appliances or
obstacles (as shown in the figure)
Installation Procedures
Ceiling Installation
(1) Use Ø10 hanger bolts, prepared on the site. Please refer to figure on the right during installation.
When the unit is installed in the ceiling,side B is to be lower than side A, for condensate discharge (as shown below).
10-15mm
10-15mm
Over 30 cm
Over 30 cm
A
A
A
B
C
B
B
Model
a
b
c
40VC009~018F-7S-QEE
Over30 cm
Over30 cm
Over2 cm
40VC024~054F-7S-QEE
Over80 cm
Over150 cm
Over10 cm
left
left
Right
Right
Ceiling
Drain pipe
Drain pipe
Correct
Wrong
Wrong
Connecting
pipe
Floor
3. Installation on the ceiling