10
09
3.2 SPACE REQUIREMENT FOR OUTDOOR UNIT
>30cm
>30cm
>200cm
>60cm
(Wall or obstacle)
Maintain channel
Air outlet
Air inlet
M
P
Air inlet
N
>60cm
Fix with bolt
Single Unit Installation
Before installation, check strength and horizontality of the base so that abnormal sound does not generate.
Fix the base firmly with anchor bolts (M10) to prevent it from collapsing.
Install the foundation and vibration-proof rubbers to directly support the bottom surface of the fixing leg that
is in contact with the bottom plate of the outdoor unit.
3.4 INSTALL THE OUTDOOR UNIT
≥
100mm
1
0
0
~
3
0
0mm
Outdoor unit
Vibration-proof rubber
Anchor bolt (M10)
Drainage (Wide 100mm x Depth 150mm)
Mortar Hole (
Φ
100mm x Depth 150mm)
>200
>50
>300
>300
>30
>60
>200
>30
Parallel connect the two units or above
Parallel connect the front with rear sides.
Connect the drain outlet with an extension drain hose
Fit the gasket onto drain outlet.
Insert the drain outlet into the base pan hole of outdoor unit, and rotate 90 degree to securely assemble them.
3.5 INSTALL THE DRAIN PIPE FOR OUTDOOR UNIT
unit:cm
unit:cm
Base pan hole
of outdoor unit
Drain hose
(Field supply)
Gasket
Drain Outlet
The mounting dimensions vary among different outdoor units.
The fixing bolt head diameter should be more than 12mm.
W
H
B
D
In regions with snowfall and cold temperatures, avoid installing the outdoor unit in areas where it
can be covered by snow. If heavy snow is expected, a field supplied ice or snow stand and/or
field supplied-installed wind baffle should be installed to protect the unit from snow accumulation
and/or blocked air intake.
CAUTION
3.3 OUTDOOR WIRE CONNECTION
Remove the electrical cover and cable clamp by loosening the screws.
Connect wires to the outdoor terminal block by same sequence to indoor unit.
Electric cover
Wire downwards to prevent
water entering control box.
L
N
S
Terminal Block
Cable Clamp
3. OUTDOOR UNIT INSTALLATION
3. OUTDOOR UNIT INSTALLATION
3.1 OUTDOOR UNIT MOUNTING DIMENSION
A
Outdoor Unit Dimentsion (mm)
Mounting Dimentsion (mm)
W
H
D
A
B
333
554
800
515
340
Outdoor Unit
38QHP009E8S
38QHP012E8S
GB
Summary of Contents for 38QHP009E8S
Page 20: ...17 7 7 12 7 13 7 14 25 7 15 18 7 7 9 7 10 10 1 10 2 7 11 BG...
Page 21: ...19 7 20 7 19 7 20 1 2 3 4 5 7 7 16 7 17 80 7 18 BG...
Page 50: ...17 7 7 12 7 13 7 14 LFL 25 OFN 7 15 OFN OFN OFN 18 7 7 9 7 10 10 1 10 2 7 11 EL...
Page 51: ...19 7 20 7 19 7 20 1 2 3 4 5 7 7 16 OFN 7 17 80 7 18 EL...