Carrier 38CKS Product Data Download Page 2

 

2

 

Money Saving Operation

 

Investment protection through long 
lasting components in harsh 
conditions.

 

Electrical Range

 

—All model sizes 

are offered in single phase 208-230 
volt.

 

Unit Design

 

—Copper tube, wavy 

aluminum 

fi

n coil is designed for 

optimum heat transfer. Vertical air 
discharge carries sound and hot 
condenser air up and away from 
adjacent patio areas and foliage. Heat 
pump style drain pan allows for easy 
removal of water, dirt, and debris.

 

Totally Enclosed Fan Motor

 

Provides greater reliability under 
adverse conditions and dependable 
performance for many years. The 
permanent split-capacitor type motor 
was designed for optimum ef

fi

ciency. 

Then, under extreme conditions, the 
motor was tested and quali

fi

ed to help 

ensure the greatest reliability.

 

External Service Valves

 

—Both brass 

service valves are front seating, with 
provision for 

fi

eld sweat connections. 

Valves are externally located for quick 
and easy refrigerant tube connections. 
Each valve provides service ports for 
ease in checking operating refrigerant 
pressures.

 

Easy Serviceability

 

—One access 

panel provides access to electrical 
controls and compressor. Removal of 
wire dome gives access to fan motor 
and removal of the top gives access to 
the coil.

 

Compressor Protection

 

— Each 

compressor is protected with internal 
temperature and current sensitive 
overloads.

 

Operating Range

 

— Minimum 

outdoor operating ambient in cooling 
mode is 55ºF (12.8ºC), maximum is 
125ºF (51.7ºC).

REGISTERED

ISO 9001:2000

Model number nomenclature

The data in this publication is displayed for all series; however, every series may not be available from manufacturer.

38CKS

018

3

A

1

10 SEER Coastal Air Conditioner

Packaging

Nominal Capacity

018 — 18,000 Btuh

042 — 42,000 Btuh

024 — 24,000 Btuh

048 — 48,000 Btuh

030 — 30,000 Btuh

060 — 60,000 Btuh

036 — 36,000 Btuh

Series

Electrical

3 — 208-230-1

Summary of Contents for 38CKS

Page 1: ...otective coating on the coil Heavy Duty Inlet Grille The WeatherArmor coil protector made of a coated steel wire grid with vertical 3 8 in 9 5 mm spacing is designed to help protect the coil from incl...

Page 2: ...nt seating with provision for field sweat connections Valves are externally located for quick and easy refrigerant tube connections Each valve provides service ports for ease in checking operating ref...

Page 3: ...125 COND COIL Face Area Sq Ft m2 Fins per In Fins per cm Rows Circuits Copper Tube Aluminum Plate Fin 6 8 63 9 1 85 9 9 92 12 4 1 15 14 8 1 37 18 5 1 72 16 1 1 50 20 8 20 8 20 8 20 8 20 8 20 8 20 8 1...

Page 4: ...or and Relay Size 042 KSAHS1601AAA Start Assist Capacitor and Relay Sizes 048 060 KAACS0201PTC Start Assist PTC All Sizes KAACH1001AAA Crankcase Heater Sizes 018 042 KAACH1201AAA Crankcase Heater Size...

Page 5: ...to the compressor motor at each start up Usage Guideline Suggested when compressor power supply is marginal Suggested in reciprocating compressor applications with rapid pressure balance RPB expansion...

Page 6: ...sure at low ambient temperatures down to 0 F 17 8 C when properly installed Usage Guideline A Low Ambient Pressure Switch or Motor Master Low Ambient Controller must be used when cooling operation is...

Page 7: ...path between the unit and service panel for a voltage drop not to exceed 2 Time delay fuse FLA Full Load Amps LRA Locked Rotor Amps MCA Minimum Circuit Amps RLA Rated Load Amps NOTES 1 Control circuit...

Page 8: ...65 2 365 1 496 9 560 4 260 4 241 3 298 5 571 5 X 571 5 036 A 571 5 862 01 81 0 19 1 93 7 460 4 501 7 565 2 365 1 496 9 560 4 260 4 241 3 393 7 571 5 X 571 5 042 A 762 0 709 61 82 6 22 2 165 1 596 9 69...

Page 9: ...0 800 380 23 800 6 97 2 43 9 80 19 500 5 71 2 79 030 3A FB4BNF030 1000 467 28 600 8 38 3 04 9 40 23 200 6 80 3 41 FB4BNF036 1000 467 28 800 8 44 3 06 9 40 23 500 6 89 3 36 FA4CN F C 030 1000 467 29 00...

Page 10: ...90 2 98 7 55 5 51 3 15 6 82 5 13 3 31 6 13 4 78 3 48 22 10 59 5 42 2 67 9 93 5 13 2 87 9 22 4 83 3 07 8 49 4 52 3 27 7 74 4 20 3 48 7 00 3 88 3 68 470 14 8 63 8 63 2 58 8 02 8 02 2 74 7 40 7 40 2 91 6...

Page 11: ...30 4 87 8 68 8 68 5 18 17 12 25 10 96 3 73 11 57 10 62 4 05 10 82 10 23 4 31 10 04 9 80 4 59 9 31 9 31 4 87 8 67 8 67 5 18 19 13 41 9 21 3 83 12 86 9 04 4 17 12 16 8 77 4 51 11 33 8 42 4 82 10 49 8 0...

Page 12: ...15 37 5 05 14 73 14 73 5 45 14 07 14 07 5 91 13 32 13 32 6 39 12 60 12 60 6 93 11 84 11 84 7 53 17 16 37 14 30 5 12 15 66 13 90 5 56 14 80 13 42 6 00 13 86 12 90 6 46 12 92 12 36 6 98 11 98 11 78 7 56...

Page 13: ...42 2 92 72 28 79 14 67 2 01 27 33 14 06 2 21 25 62 13 35 2 42 23 78 12 60 2 64 21 86 11 81 2 87 19 87 10 99 3 10 800 57 23 26 23 26 1 94 21 74 21 74 2 11 20 27 20 27 2 28 18 73 18 73 2 47 17 26 17 26...

Page 14: ...4 97 25 79 4 98 32 14 24 62 5 26 72 48 12 24 41 3 83 46 80 23 94 4 19 44 82 23 19 4 54 42 40 22 28 4 90 39 55 21 15 5 26 36 67 20 07 5 57 1400 57 39 57 39 57 3 68 37 75 37 75 3 97 35 79 35 79 4 26 33...

Page 15: ...52 46 52 46 5 05 50 29 50 29 5 45 48 01 48 01 5 91 45 47 45 47 6 39 42 99 42 99 6 93 40 41 40 41 7 53 62 55 86 48 81 5 12 53 43 47 43 5 56 50 50 45 80 6 00 47 31 44 02 6 46 44 11 42 18 6 98 40 89 40 2...

Page 16: ...88 1 91 1 94 4 TCG 9 00 8 20 7 50 6 70 6 00 5 30 4 60 4 00 SDT 30 00 35 00 40 00 45 00 49 00 53 00 58 00 62 00 KW 1 67 1 76 1 85 1 91 1 96 2 00 2 04 2 09 7 TCG 10 30 9 30 8 50 7 70 7 00 6 20 5 50 4 8...

Page 17: ...7 3 71 4 TCG 15 60 14 20 13 00 11 80 10 70 9 50 8 40 7 30 SDT 29 00 35 00 39 00 44 00 49 00 53 00 58 00 62 00 KW 2 90 3 16 3 39 3 57 3 69 3 82 3 92 3 98 7 TCG 17 80 16 10 14 70 13 40 12 20 10 90 9 70...

Page 18: ...00 35 00 40 00 45 00 50 00 54 00 59 00 64 00 KW 3 73 4 10 4 46 4 81 5 19 5 62 6 07 6 53 4 TCG 19 10 18 60 17 90 17 00 15 90 14 70 13 60 12 30 SDT 30 00 36 00 41 00 46 00 51 00 56 00 61 00 65 00 KW 3 7...

Page 19: ...1 1 94 40 TCG 30 60 27 90 25 40 23 00 20 50 18 10 15 80 13 60 SDT 86 90 95 50 103 80 112 10 120 20 128 00 136 00 144 10 KW 1 67 1 76 1 85 1 91 1 96 2 00 2 04 2 09 45 TCG 35 00 31 80 29 10 26 40 23 80...

Page 20: ...9 3 60 3 67 3 71 40 TCG 53 20 48 40 44 30 40 30 36 40 32 60 28 80 24 90 SDT 85 10 94 30 103 10 111 60 120 00 128 10 136 20 144 10 KW 2 90 3 16 3 39 3 57 3 69 3 82 3 92 3 98 45 TCG 60 80 55 00 50 20 45...

Page 21: ...60 103 70 112 40 121 10 129 80 138 60 147 40 KW 3 73 4 10 4 46 4 81 5 19 5 62 6 07 6 53 40 TCG 65 30 63 40 61 10 58 10 54 40 50 30 46 30 42 00 SDT 86 10 96 80 106 00 115 00 123 80 132 30 141 00 149 8...

Page 22: ...or interconnecting refrigerant tube lengths between 50 15 24m and 175 53 34m ft and or 20 6 1m ft vertical dif ferential consult Residential s Split System Long Line Application Guideline available fr...

Page 23: ...23...

Page 24: ...drive propeller type discharging air upward Condenser fan motors will be totally enclosed 1 phase type with class B insulation and permanently lubricated bearings Air Cooled Split System Air Condition...

Reviews: