3-2
9/24/01
3.2 Dual T1 Network Line Interfaces
3.2.1 Total Bandwidth
•
3.072 Mbps
3.2.2 DS-1 Output Signals
•
Pulse amplitude
:
2.0 V to 3.6 V ±60 Hz variations
•
Line Rate: 1.544 Mbps ±50 bps
•
Format: T1 type bipolar (except where intentional BPVs are introduced by B8ZS line
coding)
3.3 Line Codes
•
AMI or B8ZS and line code conversions between T1 lines
3.4 Framing
•
D4 (Superframe) or ESF and framing format conversions between T1 lines
3.5 Clock Source
•
Loop Timing: Selectively recovered from incoming T1 Span 1 or Span 2
•
Master Clock: Internal Enhanced Stratum 4E Crystal Oscillator ±32 ppm accuracy)
3.6 T1-to-T1 Delay
•
Latency: 3 frames maximum (0.375 ms)
3.7 T1 Channel Service Units (CSUs)
•
Integrated intelligent CSUs support all standard diagnostic functions and DS-1 or DSX-1
signal levels from 0 to -30 dB
•
Software programmable Line Build Out (LBO): 0 dB/DSX (0’-133’) (default), -7.5 dB, -
15 dB, -22.5 dB, DSX (133’-266’), DSX (266’-399’), DSX (399’-533’), DSX (533’-
655’)
•
AT&T 54016 Maintenance Messages or T1.403 Performance Report Messages (PRMs)
through 4 Kbps ESF Facility Data Link (FDL)
Summary of Contents for Access Bank II SNMP
Page 17: ...xx ...
Page 37: ...3 8 9 24 01 ...
Page 47: ...4 10 9 24 01 ...
Page 61: ...5 14 9 24 01 ...
Page 69: ...6 8 9 24 01 ...
Page 87: ...FXS ID Configuration 8 14 9 24 01 ...
Page 97: ...Battery Reversal FXS Dial Pulse Origination Card 9 24 9 24 01 ...
Page 103: ...12 Channel FXO Dial Pulse Termination Card 10 6 9 24 01 ...
Page 121: ...4 Wire E M TO Configuration 11 18 9 24 01 ...
Page 139: ...12 18 9 24 01 ...
Page 144: ...Replacing the Controller Card 9 24 01 13 5 Figure 13 3 Replacing the Controller Card ...
Page 145: ...13 6 9 24 01 ...