12-14
9/24/01
Table 12-5: T1 Test LEDs for T1 Span 1 and 2
Table 12-6: V.35 Status LED
12.12 Fault Isolation Procedures
This section lists typical trouble symptoms that may occur while operating the Access Bank II -
SNMP and suggests appropriate corrective actions to take. Fault symptoms are organized into three
groups:
•
Control Panel LED indications (system, T1 or V.35 faults)
•
Back Plate LED indications (voice circuit faults)
•
Other fault indications
State
Meaning
GREEN
Normal operations. Trunk process-
ing, self test, and network loopback
inactive.
FLASHING GREEN
T1 Self Test local loopback passed.
RED
T1 Self Test local loopback failed
due to one or more of the following
conditions: T1 Loss of Signal, Out of
Frame, Improper Line Code
Received, ESF or BPV errors
received.
YELLOW
Channels held in Trunk Processing
for this T1 span.
FLASHING YELLOW
Network loopback active for this T1
span.
State
Meaning
OFF
No T1 channels assigned to V.35
port.
GREEN
CD (RLSD) and RTS leads active. T1
channels assigned and operative.
FLASHING GREEN
V.35 in loopback to equipment.
RED
CD (RLSD) lead is inactive because
assigned T1 is inoperative.
YELLOW
CD (RLSD) lead active. RTS lead
inactive.
FLASHING YELLOW
V.35 in loopback to T1 line.
Summary of Contents for Access Bank II SNMP
Page 17: ...xx ...
Page 37: ...3 8 9 24 01 ...
Page 47: ...4 10 9 24 01 ...
Page 61: ...5 14 9 24 01 ...
Page 69: ...6 8 9 24 01 ...
Page 87: ...FXS ID Configuration 8 14 9 24 01 ...
Page 97: ...Battery Reversal FXS Dial Pulse Origination Card 9 24 9 24 01 ...
Page 103: ...12 Channel FXO Dial Pulse Termination Card 10 6 9 24 01 ...
Page 121: ...4 Wire E M TO Configuration 11 18 9 24 01 ...
Page 139: ...12 18 9 24 01 ...
Page 144: ...Replacing the Controller Card 9 24 01 13 5 Figure 13 3 Replacing the Controller Card ...
Page 145: ...13 6 9 24 01 ...