Command Line Interface (CLI)
9/24/01
14-19
14.4.4.2 alarms
Use the
alarms
command to turn on and off, the Access Bank alarms.
14.4.4.3 aps
Use the
aps
command to set or display the status of the Automatic Protection Switching.
14.4.4.4 boot
Use the
boot
command to reboot the system. All calls and connections are dropped during the reboot.
Operations
Type
Comments
To turn the Alarm Cutoff
on
aco on
To turn the Alarm Cutoff
off
aco off
To display the status of
the Alarm Cutoff
aco
Operations
Type
Comments
To set all alarms on
alarms all on
To set all alarms off
alarms all off
To set a specific alarm on
or off
alarm
[sys|vn|dn][
alarm
]on|off
To see all options for alarms, type
alarm help
To display alarms
alarms
Operations
Type
Comments
To set either d1 or d2 as
the primary span
aps primary d
n
To set BPV switch
threshold to 10^-n,
4<=n<=6
aps threshold
n
To display APS status
aps