Configuring the Access Bank
9/24/01
6-5
8. Check the configuration of T1 port #1:
Access Bank II> ds1 1
- DS1 d1
ds1 d1
circuitid "T1 Circuit AD456-7Y"
ds1 d1
csu on
ds1 d1
lbo dsx0|csu0
ds1 d1
linetype d4
ds1 d1
linecode b8zs
ds1 d1
prm att
•
To change the framing and then check the configuration:
Access Bank II> ds1 1 linetype esf
Access Bank II> ds1 1
- DS1 d1
ds1 d1
circuitid "T1 Circuit AD456-7Y"
ds1 d1
csu on
ds1 d1
lbo dsx0|csu0
ds1 d1
linetype esf
ds1 d1
linecode b8zs
ds1 d1
prm att
•
To remove all the connections between T1, Analog, and V.35 ports:
Access Bank II> kill d1
Access Bank II> kill d2
•
To set the connections (example is channels 1-12 of T1 #1 to V.35 port, channels 13-24
of T1 #1 to FXS card in first analog slot):
Access Bank II> make v1 d1:1 12
Access Bank II> make d1:13 f1:1 12
Access Bank II> connections
1) Span d1: "T1 Circuit AD456-7Y"
v1:01 v1:02 v1:03 v1:04 v1:05 v1:06 v1:07 v1:08 v1:09 v1:10 v1:11 v1:12
f1:01 f1:02 f1:03 f1:04 f1:05 f1:06 f1:07 f1:08 f1:09 f1:10 f1:11 f1:12
2) Span d2: "T1 Port #2 - Not in Service"
Summary of Contents for Access Bank II SNMP
Page 17: ...xx ...
Page 37: ...3 8 9 24 01 ...
Page 47: ...4 10 9 24 01 ...
Page 61: ...5 14 9 24 01 ...
Page 69: ...6 8 9 24 01 ...
Page 87: ...FXS ID Configuration 8 14 9 24 01 ...
Page 97: ...Battery Reversal FXS Dial Pulse Origination Card 9 24 9 24 01 ...
Page 103: ...12 Channel FXO Dial Pulse Termination Card 10 6 9 24 01 ...
Page 121: ...4 Wire E M TO Configuration 11 18 9 24 01 ...
Page 139: ...12 18 9 24 01 ...
Page 144: ...Replacing the Controller Card 9 24 01 13 5 Figure 13 3 Replacing the Controller Card ...
Page 145: ...13 6 9 24 01 ...