background image

 
 
 

 
 
 
 
 

USER MANUAL 

 

FOR 

 

G38900014  

 

Configuration Software

 

Check  

www.dupline.com/downloads

 

 
for latest version of software 
and manual 

(Specifications are subject to change without notice 20.04.2001 

Summary of Contents for G38900014

Page 1: ...USER MANUAL FOR G38900014 Configuration Software Check www dupline com downloads for latest version of software and manual Specifications are subject to change without notice 20 04 2001...

Page 2: ...ndows 95 98 and NT and requires at least 486 processor with 8 Mbytes RAM or higher A free serial port Com1 or Com2 5 Mbytes hard disk for installation Screen resolution of 640 x 480 pixels 256 colours...

Page 3: ...data Open Open existing file Save Save file Save As Save file under new name Write Generator Write data to the Generator Read Generator Read data from the Generator Print The following options are av...

Page 4: ...ie master commands can be transferred from one network to the other SMS Set up For sending status and receiving commands to from a GSM phone via the Dupline GSM8 modem Access to the Master Generator i...

Page 5: ...mbol indicating the selected channel type Click on the symbol with left mouse button and the parameters which can be set for that particular channel function can be viewed in the properties window The...

Page 6: ...re Tool tip When the curser is positioned on a channel button a bar appears indicating channel number describing channel type and showing the user defined channel description 2001 Carlo Gavazzi Indust...

Page 7: ...t checkbox time and date is transferred from the PC to the G38900014 The program shows the updated time and date from the Windows System for checking If the PC does not show the correct time the clock...

Page 8: ...text window for description For all gate fields there are Tool Tips showing valid entries Click on F1 for help All inputs are as standard If an input should be the is put in front of the address eg D...

Page 9: ...ption is sent out on a printer on the parallel port If the Channel Events output to in the Basic Setup is set to SMS Message the change will be sent as an SMS message User description of the channel T...

Page 10: ...annel The On delay is started by a short pulse Entering of On delay Additional channel with which the function is enabled Entering of Off delay When the timer function is changed the icon of the chann...

Page 11: ...n for switching ON or switching OFF In this case the channel will switch off on weekdays at 23 00 but not on Saturdays and Sundays Note By entering a minus in the time field the ON time OFF time is de...

Page 12: ...aster function or an alarm channel Pop Up menu appears by clicking right mouse button The master function is to include a real time function When a real time function is included a matrix can be opene...

Page 13: ...ler blinds is given priority Delay before the roller blind changes direction The reverse Up time defines for how long the roller blinds must run in the opposite direction after expiry of the roll time...

Page 14: ...which a second pair of limit values can be entered Entry of the address which is to enable the second pair of limit values When selecting this option the Analink signal is provided by another Analink...

Page 15: ...signed ISA Operation mode either Standard or Auto reset In Auto reset mode the Reset channel cannot be selected By activating the Disable channel the detector is removed from the alarm surveillance En...

Page 16: ...the set Disable channel the detector is removed from the alarm surveillance The water and smoke alarm are designed identically Only one Alarm siren and one Alarm signal channel can be selected for the...

Page 17: ...bled by another channel as is the case with water and smoke detectors Additional channels can be selected to flash together with the alarm output channel Click here to call a matrix in which the desir...

Page 18: ...2001 Carlo Gavazzi Industri A S All rights reserved 17 Common siren Selection of alarms using common siren The set siren time applies to this channel only The times are identical with the times specif...

Page 19: ...e On delay period The timer restarts counting upon each start of transmission Only upon uninterrupted transmission for the On delay period will the receiver turn on Channel Off delay Channel controlle...

Page 20: ...channel types When transmission takes place on this channel the switch pattern is transferred to the selected basic channels to force these into the predefined status Parameters Definition of the swit...

Page 21: ...ssion pulse longer than 1 sec causes the output to be manually controlled and will keep the Up direction on until transmission is released If a Down pulse is issued while running in Up direction the d...

Page 22: ...oll at the same time In sequential operation manual operation cannot take place Two channels The received output on the Master Up and Master Down channel will reflect the last opera tion performed by...

Page 23: ...el When this option is selected the analog value cannot be transmitted for display via this channel Inversion of switching function The switching function can be inverted in relation to the limit valu...

Page 24: ...smission on channel If missing transmission outlasts the input delay the input signals fail and the channel will start flashing If the input signal failure has been acknowledged the channel will stay...

Page 25: ...lace on the channel Upon missing transmission for more than 10 secs the input will register water and the channel will start flashing Upon transmission on the assigned Disable channel the input zone i...

Page 26: ...he detector reacts on an error signal Smoke alarm Passive detector Operation Normally open input no transmission on channel The detector signals when transmission takes place on the channel Upon trans...

Page 27: ...Upon enabling of a disabled detector 10 secs will elapse before the detector reacts on an error signal Intruder alarm Passive detector input Operation Normally open input no transmission on channel G...

Page 28: ...d when the house is empty Parameters Armouring delay desarmouring delay Note By activating door lock or code lock armouring manual armouring can be desarmoured in case somebody comes home after manual...

Page 29: ...e Siren sounds This will prevent the alarm signal channel from reacting c The alarm is not switched off but the Siren has stopped d After elapse of the alarm signal delay the alarm will restart the mo...

Page 30: ...ration The internal Real time clock Hours and minutes is output on selected channels in a 4 digit BCD format Transmission on these channels will not change the receiver output but can be used as input...

Page 31: ...tput from the Logic is written to channel or flag Writing a channel always means activating a transmitter on the channel A channel kept activated by a transmitter or a master function cannot be switch...

Page 32: ...us RTU is implemented with the function of a slave The following Modbus functions are supported 01 02 03 05 06 and 16 All 128 Dupline Digital Analink Counter and BCD channels are placed as follows Mod...

Page 33: ...LO KL F Input Table 864 360 0 HI LO MN 0 Input Table 879 36F F HI LO MN F Input Table 880 370 0 HI LO OP 0 Input Table 895 37F F HI LO OP F Input Table 1000 1000 B8 B1 A8 A1 Digital 1001 1001 D C Dig...

Page 34: ...HI LO CD F Output Table 4896 1320 0 HI LO EF 0 Output Table 4911 132F F HI LO EF F Output Table 4912 1330 0 HI LO GH 0 Output Table 4927 133F F HI LO GH F Output Table 4928 1340 0 HI LO IJ 0 Output T...

Page 35: ...at a time until an acknowledge ment is received Once an acknowledgement is received no further calls are made Acknowledgement takes place by receipt of a message from the called number Indicates the...

Page 36: ...d up as an alarm application with 4 intruder alarms E1 to E4 1 code armering E5 2 motion detectors used in the intruder alarm E6 and E7 2 smoke alarms F1 and F2 1 common sirene F3 1 Reset button for r...

Page 37: ...number within this time the event is acknowledged if not the next number will be called Select if an event causes a call to all entered phone numbers simultaneously or call one number at a time until...

Page 38: ...SM phone If more Dial out Phone numbers has been setup an acknowledge can be sent to the Master Generator by sending an empty SMS message back and the Master Generator will then stop sending messages...

Page 39: ...This option will activate Password protection All received SMS messages will be checked for the correct password before any communication to the Master Generator can take place Enter the phone number...

Page 40: ...option Controlling Command Example Password Channel argument 1234 F4 on 1234 f4 off 1234 Alarm reset on Request Command Example Password Channel 1234 F3 alt 1234 F3 1234 Siren Without Password option...

Page 41: ...Off 2 Inputs On Off Code Lock arm On Off Door Lock arm On Off Manual arm On Off 1 Siren Alarm On Off 2 Inputs On Off Reset On Off 1 Siren Alarm On Off 1 Common Siren On Off Timer Recycler No event No...

Page 42: ...Siren Alarm Illegal 3 Illegal 3 Current status Inputs Illegal 3 Illegal 3 Current status Siren Alarm Illegal 3 Illegal 3 Current status Manual Arm Illegal 3 Illegal 3 Current status Code Door Arm Ille...