Spectra II
Control inputs and outputs
09.16
Serviceanleitung
65
Identification
Pin
Description / Function
+ 5 VDC
EXT
25
5 Volt DC output for external use. Max. 1 A.
This voltage is provided from direct print module and can be used
e.g. as control voltage. Never apply any external voltage to this
output.
+ 24 VDC
EXT
26
24 Volt DC output for external use. Max. 1 A.
This voltage is provided from direct print module and can be used
e.g. as control voltage. Never apply any external voltage to this
output.
Plug Connector
Type
D-Sub connector High Density
26-pin. / connector
Manufacturer
W+P-Products
Reference number
110-26-2-1-20
Output Voltages (connected with GND-PE)
+ 24 V / 1 A
Fuse: Polyswitch / 30 V / 1 A
+ 5 V / 1 A
Fuse: Polyswitch / 30 V / 1 A
Port 1 - 15
Input
Tension
5 VDC … 24 VDC
Impedance
47Ω + (100nF || 10 kΩ)
Output
Tension
5 VDC … 24 VDC
Impedance
47Ω + (100nF || 10 kΩ || 47Ω)
Current max.
High +15 mA
Low -15 mA
Port 16
Input
Tension
5 VDC … 24 VDC
Impedance
100nF || 10 kΩ
Output
Tension
5 VDC … 24 VDC
Impedance
100nF || 10 kΩ
Current max.
High +500 mA (Darlington BCP56-16)
Low - 500 mA (Darlington BCP56-16)
Optocoupler
Output
TCMT4106, CTR 100% - 300%, Vishay or
TLP281-4(GB), CTR 100% - 600%, Toshiba
Input
TCMT4106, CTR 100% - 300%, Vishay or
TLP281-4(GB), CTR 100% - 600%, Toshiba
Input
Option 2nd LED
TCMT4600, CTR 80% - 300%, Vishay or
TLP280-4, CTR 33% - 300%, Toshiba
Technical data
Summary of Contents for Spectra II
Page 1: ......
Page 12: ......
Page 18: ......
Page 46: ......
Page 52: ......
Page 62: ......
Page 68: ......
Page 69: ...Spectra II Wiring Plan 09 16 Service Instructions 67 10 Wiring Plan Figure 36 ...
Page 70: ...Wiring Plan Spectra II 68 Service Instructions 09 16 Figure 37 ...
Page 72: ...Wiring Plan Spectra II 70 Service Instructions 09 16 10 2 Power Electronics Figure 39 ...
Page 76: ......