7.3 Dispensing unit
A
C
B
C
D
E
Figure 28
1. Remove tear off edge (if mounted) at the front of printer.
2. For an easier handling, remove front plate (if mounted) which is
fixed at the printer base.
3. Pull the knurled knob (A) to open the dispenser rocker.
4. Place the dispenser unit (B) before the pressure roller. Fix it with
Allen screws (C) at the aluminium profile below the pressure roller
5. Engage again the dispenser rocker.
1. Remove tear off edge (if mounted) at the front of printer.
2. For an easier handling, remove front plate (if mounted) which is
fixed at the printer base.
3. Pull the knurled knob (A) to open the dispenser rocker.
4. Place the dispensing unit (B) before the pressure roller. Introduce
the photocell cable (D) between the chassis and the left
supporting plate of the dispenser downwards.
5. Fix the dispensing unit with the hex. head screws (C) at the
aluminium profile beneath the pressure roller.
6. Engage again the dispenser rocker.
7. Insert the plug of photocell cable (D) into the female connector (E)
and fasten it.
Dispensing unit
without photocell
Dispensing unit
with photocell
Summary of Contents for Spectra II
Page 1: ......
Page 12: ......
Page 18: ......
Page 46: ......
Page 52: ......
Page 62: ......
Page 68: ......
Page 69: ...Spectra II Wiring Plan 09 16 Service Instructions 67 10 Wiring Plan Figure 36 ...
Page 70: ...Wiring Plan Spectra II 68 Service Instructions 09 16 Figure 37 ...
Page 72: ...Wiring Plan Spectra II 70 Service Instructions 09 16 10 2 Power Electronics Figure 39 ...
Page 76: ......