2.12 General connection diagram
G
G0
G
G0
VBA
T
CO
M
A
NO
A
1
3
2
4
NET
Tx/Rx
GND
DI1
S4
S3
S2
S1
GND
DI2
VREF
2 AT
24 Vac
230 Vac
35 VA
shield
shield
shield
shield
with batt
er
y
without batt
er
y
G
G0
VBAT
COMx
NOx
1
3
2
4
Sporlan
SEI / SEH
/ SER
DANFOSS
ETS / CCMT
E
VD4
PC
EVD4 ser
vice USB adapt
er
EE
V driv
er
4
T
x/Rx
GND
pCO
GND
GND
RS485
Modbus®
pCO
1
20
21
4
EVDCNV00E0
CVSTDUM0R0
pCO
Analog - Digital Input
Network
OPEN A
CLOSE A
OPEN B
CLOSE B
A
B
C
OMB
NOB
1
3
2
4
G G0
VBA
T
EVD
G
G0
VBA
T
35 VA
ULTRACAP
24 Vac
230 Vac
2 AT
EVD evolution
TWIN
shield
TRADRFE240
TRADRFE240
4
1
2
3
CAREL E
X
V
VALVE B
CAREL E
X
V
VALVE A
8
9 10 11
12
13
23
S
A
17
18
19
14
S
B
15
16
7
6
1
20
4
21
22
3
4
21
ALCO
EX5/6
EX7/8
5
1
4
C
D
E
F
B
Tx/Rx
GND
DI1
S4
S3
S2
S1
GND
DI2
VREF
1
21
20
4
4
21
3
A
EVD0000T0*: tLAN version
EVD0000T3*: tLAN version
EVD0000T1*: pLAN version
EVD0000T4*: pLAN version
EVD0000T2*: RS485 version
EVD0000T5*: RS485 version
1
2
Tx/Rx
GND
DI1
S4
S3
S2
S1
GND
DI2
VREF
Tx/Rx
GND
DI1
S4
S3
S2
S1
GND
DI2
VREF
Tx/Rx
GND
DI1
S4
S3
S2
S1
GND
DI2
VREF
Tx/Rx
GND
GND
DI1
S4
S3
S2
S1
GND
DI2
VREF
1
20
Tx/Rx
DI1
S4
S3
S2
S1
GND
DI2
VREF
L
2
Fig. 2.o
Key:
1
green
21
black
2
yellow
22
blue
3
brown
23
computer for configuration/supervision
4
white
A
Connection to EVD0000UC0
5
computer for configuration
B
Connection to ratiometric pressure transducer (SPKT00**R0)
6
USB/tLAN converter
C
Connection to electronic pressure probe (SPK**0000) or piezoresistive
pressure transducer (SPKT00*C00)
7
adapter
8
ratiometric pressure transducer driver A
D
Connection as positioner (4 to 20 mA input)
9
NTC probe driver A
E
Connection as positioner (0 to 10 Vdc input)
10
ratiometric pressure transducer driver B
F
Connection to combined pressure/temperature probe (SPKP00**T0)
11
NTC probe driver B
L
Connection to Float level sensor (cod. LSR00*3000)
12
digital input 1 configured to enable driver A control
1
The maximum length of the connection cable to the EVD0000UC0 module
is 5 m.
13
digital input 2 configured to enable driver B control
14
voltage-free contact (up to 230 Vac) driver B
2
The connection cable to the valve motor must be 4-wire shielded, AWG 22
Lmax= 10 m or AWG14 Lmax= 50 m.
15
solenoid valve driver B
16
alarm signal driver B
17
voltage-free contact (up to 230 Vac) driver A
18
solenoid valve driver A
19
alarm signal driver A
20
red