8
ENG
ir0300028EN rel. 1.1 - 05.05.2017
1.2 Accessories
IROPZKEY00/A0 programming key
The IROPZKEY00 and IROPZKEY00A0 (powered) programming keys can
be used with the ir33+ platform controllers. Visual Parameter Manager
(VPM) allows up to 7 diff erent confi gurations (sets) of parameters to be
loaded onto the controller (the controller operating parameters plus 6
sets of customisable parameters). The read/write operations are carried
out with the controller off .
IROPZKEY00
IROPZKEYA0
Fig. 1.c
Fig. 1.d
Connection cable (P/N PSTCON0*B0)
Three-wire cable to connect the controller to the tLAN interface card (P/N
IROPZDSP00). Available in diff erent lengths: 1.5; 3; 5 m.
Fig. 1.e
tLAN interface card (P/N IROPZDSP00)
The tLAN interface card for remote display is an electronic device used
to connect the controller to a remote display. See the instruction sheet
(+050003860).
Fig. 1.f
Remote display
The remote display can be used to display one of the system variables.
Versions are available for ir33+ (P/N IREVXGD000) and ir33+ wide, ir33+
wide small, easy wide, easy small wide (P/N PST00VR100). See the
instruction sheet (+050003920).
IREVXGD000 PST00VR100
Fig. 1.g
Fig. 1.h
RS485 serial interface (P/N IROPZ48500 and IROPZ485S0)
Plugged directly into the programming key connector, this provides
connection to the PlantVisor supervisory system. The accessory has been
designed as a plug-in addition to the controller and consequently can
be installed following installation if needed. Model IROPZ485S0 features
a microprocessor and can automatically recognise the TxRx+ and TxRx-
signals (reverse connection).
Fig. 1.i
VPM programming tool (Visual Parameter Manager)
The program can be downloaded from http://ksa.carel.com. The tool
runs on a computer and is used to set up the controller, change the
parameter settings and update the fi rmware. The USB/I2C converter P/N
IROPZPRG00 is required.
Fig. 1.j
USB/I2C converter and cable (P/N IROPZPRG00)
Converter used to connect a personal computer to an IROPZKEY00/
A0 programming key, and consequently use the VPM program
(Visual Parameter Manager) to read, set and write the parameters. The
programming key can then be used to program the controllers or read
the controller parameters, and for example copy a confi guration from
one controller to the others.
Fig. 1.k
Light sensor (P/N PSOPZLHT00)
To be installed in the door jamb or inside the cold room
Fig. 1.l