8528-M372-O1 Rev E
PZ3000 Series
6
POWER CONNECTION, CONT.
15. Insuring no wires are between the battery door and the back of the indicator, lower the
battery door.
16. Install the two screws and washers removed in step 4. NOTE: The PZ3015 and PZ3030
use thumbscrews and should be finger-tightened only.
17. Return the indicator to the scale, wall or table stand.
18. Apply power to the PZ3000 using the power supply, to begin charging the new batteries.
19. The scale is now ready for operation.
Extended Battery Operation
In operations that require the remote use (no AC power) of the scale beyond the approximately
50 hours of continuous use, an auxiliary battery door assembly (CPN 8528-C365-0A) and 6 “AA”
size, 2300 mAh minimum batteries (CPN 6800-0020) can be purchased to easily accommodate
your operation.
The following steps describe how to remove the battery door and re-charge the batteries
externally using the AC power adapter (battery charger).
1. Remove the indicator from the scale, wall or table stand.
2. Turn the indicator so that the display is facing away from you and place it face down on a
table or bench.
3. Referring to Figure No.2, locate the two screws on the angled edge of the indicator and
remove the screws and washers under them. NOTE: The PZ3015 and PZ3030 use two
thumbscrews and the PZ3060 uses two socket head cap screws.
4. Referring to Figure No. 6 remove the connector from the end of the battery holder and
then remove the battery door and set it aside.
5. Place the auxiliary battery door with fully recharged batteries on the indicator and then
re-connect the connector to the end of the battery holder. See Figure No. 6.
6. Insuring no wires are between the battery door and the back of the indicator, lower the
battery door and install the two screws and washers removed in step 3. NOTE: The
PZ3015 and PZ3030 use thumbscrews and should be finger-tightened only.
7. Return the indicator to the scale, wall or table stand. The scale is ready for operation.
8. Place the battery door removed in step 5 on a table or bench with the battery holder and
battery strap up.
Figure No. 5
6 “AA” Size NiMH Batteries
(2300mAh minimum)
-
+
+
-
+
-
+
-
-
+
-
+
Summary of Contents for Detecto PZ3000 Series
Page 2: ......
Page 19: ...8528 M372 O1 Rev E PZ3000 Series 17 PARTS IDENTIFICATION PZ3015 Base Assembly ...
Page 21: ...8528 M372 O1 Rev E PZ3000 Series 19 PARTS IDENTIFICATION PZ3015L PZ3030 Base Assembly ...
Page 23: ...8528 M372 O1 Rev E PZ3000 Series 21 PARTS IDENTIFICATION PZ3060 Base Assembly ...