Cardin Elettronica 310/GL20A Instruction Manual Download Page 15

15

70mm

230mm

A

Montaggio base di fissaggio

GL20   

 

20-11-94

dM0005

Description :

Product Code :

Date :

Drawing number :

P.J.Heath

CARdIN ELETTRONICA S.p.A

  - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831

Draft : 

All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law 

GL20

H

B

d

B

E

F

G

C

M

N

L

•  These instructions are aimed at professionally qualified "

INSTALLERS 

OF ELECTRICAL EQUIPMENT

" and must respect the local standards 

and regulations in force. All materials used must be approved and must 

suit the environment in which the installation is situated.

•  All maintenance operations must be carried out by professionally qualified 

technicians. Before carrying out any cleaning or maintenance operations 

make sure the power is disconnected at the mains. 

•  This appliance must be used exclusively for the purpose for which it 

has been made. "i.e. 

for the automation of counterbalanced garage 

doors

" Any non authorised modifications are to be considered improper 

and therefore dangerous. The manufacturer accepts no liability for situ-

ations arising from an installation which does not conform to the local 

standards and regulations in force.

IMPORTANT!

 The geared motor 

310/GL2024

 is not fitted with 

a torque limiter. Only use an electronic programmer which has a 

torque limiter with maximum force at the head of the gate equal 

to 

150N

 (local standards and regulations in force).

USE

The appliance may be used to operate single or articulated garage door of 

up to 

15m

2

 with a maximum weight of 

100kg

 (central motor).

For garage doors with a width of over 

4m

 and not more than 

2,70m

 in height 

(max. weight 

180kg

) and for garage doors with a pedestrian access door two 

motors are required (one motor with electronics and one without).

310/GL20A

Self-locking electromechanical operator without on board electronics.

310/GL20AP08

Self-locking electromechanical operator with an incorporated programmer 

automatic, semi-automatic, limited opening, torque limiter, electric locking 

device and 

S486 

decoder.

310/GL20AP09

Self-locking electromechanical operator with an incorporated programmer 

automatic, semi-automatic, limited opening, torque limiter, electric locking 

device and 

S449 

decoder.

It is the responsibility of the installer to make sure that the following public 

safety conditions are satisfied:

1)  The pedestrian door must not open on its own, e.g.; swing open while 

the garage door is in movement

2)  The appliance must not be operated when the pedestrian door is not fully 

closed.

3)  Make sure that there are no dangerous sharp edges (R=3mm min.)

4)  Make sure that the end-user is aware that children and/or pets must not 

be allowed to play within the area of a garage door installation. If possible 

include this in the warning signs.

5)  A  correct  earth  connection  is  fundamental  in  order  to  guarantee  the 

electrical safety of the machine

6)  If you have any questions about the safety of the gate operating system, 

do not install the operator. Contact your dealer for assistance. 

TECHNICAL dESCRIPTION

•  Single piece geared reduction unit.

•  Single phase drive motor with an incorporated overload protector and a 

permanently lubricated reversible reduction unit mounted on a cast iron 

stator.

•  Manual release mechanism

•  Base in zinc-plated steel 

•  Carter in shock-proof plastic

•  Night light

ACCESSORIES

316/GLO2Ad 

-  Straight telescopic arm length 700.

316/GLO3A 

-  Curved (right) telescopic arm length 700.

316/GLO4A 

-  Curved (left) telescopic arm length 700.

316/GLO6A 

-  Straight telescopic arm length 1000.

316/GLOPS 

-  Motor support extension.

316/GLOTG 

-  Pair of pipes, pipe support brackets and DIN  

 

 

 

threaded pins for central motor positioning.

316/GLOCGL

   -  Ferrule and DIN threaded pin, with pipe support    

 

 

brackets for lateral motor positioning.

316/GL20SB 

-  Manual release cord.

Attention!

 Only for EU customers - 

WEEE marking

.

This symbol indicates that once the products life-span has expired 

it must be disposed of separately from other rubbish. The user 

is therefore obliged to either take the product to a suitable dif-

ferential collection site for electronic and electrical goods or to 

send it back to the manufacturer if the intention is to replace it 

with a new equivalent version of the same product.

Suitable differential collection, environmental friendly treatment and disposal 

contributes to avoiding negative effects on the ambient and consequently 

health as well as favouring the recycling of materials. Illicitly disposing of this 

product by the owner is punishable by law and will be dealt with according 

to the laws and standards of the individual member nation.

During the opening/closing manoeuvre check for correct operation and acti-

vate the emergency stop button in case of danger. The appliance must not be 

activated in the dark therefore make sure that the night lights function correctly. 

The appliance can be manually released in case of emergency (see manual 

release on page 17). Periodically check the moving parts for wear and tear and 

grease if required, using lubricants which maintain their friction levels unaltered 

throughout time and are suitable for temperatures of 

-20 to +70°C

Periodically check the correct operation of all safety devices (photoelectric 

cells etc.). Eventual repair work must be carried out by specialised person-

nel using original spare parts. The appliance is not suitable for continuous 

operation and must be contained within the value stipulated (see technical 

data on page 36).

The minimum controls which may be installed are OPEN-STOP-CLOSE, these 

controls  must  be  installed  in  a  location  not  accessible  to  children.  Before 

starting with the installation of the system check that the structure which is 

to be automated is in good working order and respects the local standards 

and regulations in force.  Automating an existing system which has sliding or 

balancing problems will not solve those problems and may even make them 

worse by placing more stress on weakened or damaged areas.  To this end make 

sure that the runner guides slide freely and grease all the moving parts (pins, 

castors etc.) using lubricants which maintain unaltered friction characteristics 

over a period of time and are suitable for temperatures of 

-20 to +70°C

.

FITTING THE UNIT

Fitting the motor centrally

1)  Remove the motor from its positioning base 

"A"

 fasten the two motor base 

extensions "

B

" to the positioning base. Mark the position of the motor axis 

on the positioning base "

A

" and fasten the complete profile "

A

" and "

B

" to 

the cross piece of the garage door. The motor axis must be 70 mm below 

the hinged point of the door arm "

C

". (for non flush fitting garage doors) or 

half way up for flush fitting garage doors (see figs 2-3). The motor support, 

complete with its extensions, must be fitted to the side of the lock and has 

to cover at least three cross pieces "

d

", "

E

" and "

F

" using a minimum of 

three 

Ø 5mm

 rivets for each cross piece.

IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS

9

IMPORTANT REMARKS  

IMPORTANT REMARKS  

IMPORTANT REMARKS 

 USER INSTRUCTIONS

REAd  THE  FOLLOWING  REMARKS  CAREFULLY  BEFORE  PROCEEdING  WITH  THE  INSTALLATION. 

PAY  PARTICULAR  ATTENTION  TO  ALL  THE  PARAGRAPHS  MARKEd  WITH  THE  SYMBOL 

.  NOT 

REAdING  THESE  IMPORTANT  INSTRUCTIONS  COULd  COMPROMISE  THE  CORRECT  WORKING 

ORdER  OF  THE  SYSTEM  ANd  CREATE  dANGER  SITUATIONS  FOR  THE  USERS  OF  THE  SYSTEM.

Summary of Contents for 310/GL20A

Page 1: ...trico per 2 motori Pagina 9 Avvertenze importanti Pagina 10 Istruzioni per l uso Pagina 10 Istruzione per l installazione Pagina 10 11 Sblocco manuale Pagina 12 Programmatore elettronico Pagina 12 14...

Page 2: ...e 6 Clignoteur externe 7 Antenne externe C ble coaxial RG58 Imp dance 50 8 Commutateur du mur TB TD 9 Bo te de d rivation 10 Interrupteur omnipolaire avec ouverture des contacts d au moins 3 mm 11 C b...

Page 3: ...hts reserved Unauthorised copying or use of the information contained in this document is punishable by law 316 GLO2Ad 316 GLOPS 316 GLO4A 316 GLO3A 316 GLO2Ad 316 GLOTG Z 316 GLOPS 316 GLOPS2 INSTALL...

Page 4: ...SB All rights reserved Unauthorised copying or use of the information contained in this document is punishable by law 316 GLO6A 316 GLOPS 316 GLO6A 316 GLOTG Z 316 GLOPS2 316 GLOPS INSTALLAZIONE DI 1...

Page 5: ...438 401831 Draft GL20 316 GL20SB All rights reserved Unauthorised copying or use of the information contained in this document is punishable by law 316 GLO2Ad 316 GLO4A 316 GLO3A 316 GLOPS 316 GLOPS 3...

Page 6: ...316 GL20SB All rights reserved Unauthorised copying or use of the information contained in this document is punishable by law 316 GLO2Ad 316 GLO4A 316 GLOPS 316 GLO3A 316 GLOPS 316 GLOPS 316 GLOPS 316...

Page 7: ...ined in this document is punishable by law GL20 C 100 mm A B All rights reserved Unauthorised copying or use of the information contained in this docum N Q S All rights reserved Unauthorised copying o...

Page 8: ...ged if there is no motor 2 LP Warning lights FTC RX Photocell receiver FTC TX Photocell projector FCA Opening travel limit motor 1 PS Pressure switch for anticrush buffer SEL Mechanical selector switc...

Page 9: ...LP Warning lights FTC RX Photocell receiver FTC TX Photocell projector FCA Opening travel limit motor 1 FCC Closing travel limit motor 2 PS Pressure switch for anticrush buffer SEL Mechanical selector...

Page 10: ...ritto L 1000 316 GLOPS Prolunga piastra motore 316 GLOTG Coppia tubi staffe supporto tubo e perni dentati DIN per montaggio di un motore centrale 316 GLOCGL Boccola e perno dentato DIN con staffa supp...

Page 11: ...rfettamente in linea Montaggio laterale Una volta individuato il corretto schema di montaggio procedere come indicato al punto 1 2 3 e 7 della descrizione di montaggio precedente In questo caso i sup...

Page 12: ...a frequenza di rete corrispondano ai valori riportati nella targhetta caratteristiche L apparecchiatura funziona con tensione monofase 230V 50Hz Il motoriduttore deve essere collegato ad un efficace i...

Page 13: ...rosegue fino alla successiva pressione sul tasto P1 Alla terza pressione si ha l uscita dalla modalit di programmazione con la memo rizzazione dei parametri nella EEPROM tali parametri vengono subito...

Page 14: ...solo in fase di chiusura Pos B Dip 1 OFF Dip 2 OFF Richiusura automatica esclusa modalit di fun zionamento del tasto dinamico normale con la sequenza Apre Blocco Chiude Blocco Pos C Dip 1 ON Dip 2 OFF...

Page 15: ...r positioning 316 GLOCGL Ferrule and DIN threaded pin with pipe support brackets for lateral motor positioning 316 GL20SB Manual release cord Attention Only for EU customers WEEE marking Thissymbolind...

Page 16: ...extreme right and left of the garage door maintaining a distance of 65mm from the counterweight housing as shown in the drawing Insert the threaded joint of the telescopic arm directly into the threa...

Page 17: ...or User the lowest hole on the motor support bracket A fig 9 to pass the cable into the appliance To connect the appliance follow the wiring diagram on page 8 The microswitch located on the an eventua...

Page 18: ...essed a third time the system exits the programming mode and memorises the parameters under EEPROM the parameters are checked straight away and if the result is positive LED L1 will switch off and the...

Page 19: ...ng the sequence Open Block Close Block Pos C Dip 1 ON Dip 2 OFF Automatic reclosing excluded limited dynamic button mode using the sequence Open Close with travel direction inversion only during the c...

Page 20: ...s triers support de l l ment tubulaire axes denture DIN pour montage d un moteur central 316 GLOCGL Douille et axe denture DIN avec trier de support de l l ment tubulaire pour montage d un moteur lat...

Page 21: ...as viter d utiliser le ressort M en raison du fait que la poign e doit rester dans la position de d verrouillage R glage du fin de course Placer manuellement la porte envi ron 50mm de la position d ou...

Page 22: ...de zone 230V 40W Il est conseill d utiliser un conduit isolant pour le passage des c bles sur le tablier de la porte basculante Pour introduire les c bles dans l appareil se servir du trou le plus bas...

Page 23: ...matique le comptage continue se d rouler jusqu la pression suivante sur la touche P1 la troisi me pression on quitte la programmation avec mise en m moire EEPROM des param tres tels param tres sont im...

Page 24: ...e marche seulement en phase de fermeture Pos B Dip 1 OFF Dip 2 OFF Refermeture automatique invalid e mode de fonc tionnement normal de la touche dynamique dans la s quence Ouvre Arr t Ferme Arr t Pos...

Page 25: ...ur Montage eines zentralen Motors 316 GLOCGL Buchse und nach DIN gezahnter Bolzen mit Rohrtr gerb gel zur Montage eines seitlichen Motors 316 GL2OSB Seilzugentriegelung Achtung Nur f r EG Kunden WEEE...

Page 26: ...es direkt in die gezahnte Getriebemotorwelle einf hren sie bis zum Anschlag bringen und mit dem mitgelieferten Stift befestigen Die Ausgleichung des Torblattes durch die manuelle Bet tigung des Schwin...

Page 27: ...ht in der N he der Gl hbirne des Wachlichtes 230V 40W verlegt werden Es ist ratsam eine Kabelf hrung aus isolierendem Material f r die Verlegung der Kabel auf dem Schwingtorblatt zu verwenden F r den...

Page 28: ...dritten Tastendruck erfolgt der Austritt aus dem Programmiermodus mit der Speicherung der Parameter im EEPROM Diese Parameter werden sofort berpr ft und wenn das Verfahren erfolgreich abgeschlossen w...

Page 29: ...it der Sequenz ffnen Blockierung Schliessen Blockierung Pos C Dip 1 ON Dip 2 OFF Automatische Schlie ung ausgeschlossen begrenzte Funktionsweise der dynamischen Taste mit der Sequenz ffnen Schliessen...

Page 30: ...n Atenci n Solo para clientes de la Uni n Europea Marcaci n WEEE Els mboloindicaqueelproducto unavezterminadasuvida til debe ser recogido por separado de los dem s residuos Por lo tanto el usuariodeb...

Page 31: ...M podr a desarrollar una fuerza excesiva indeseable y que podr a producir el retorno de la manilla de la cerradura A Si ocurre esto no utilizar el resorte M puesto que la manilla debe quedarse en la...

Page 32: ...bulbo de la l mpara 230V 40W Se aconseja el uso de una roza en material aislante para el paso de los cables por la hoja de la puerta basculante Utilizar como entrada de los cables en el equipo el orif...

Page 33: ...uenta sigue adelante hasta la sucesiva pulsaci n de la tecla P1 Con la tercera pulsaci n se sale de la modalidad de programaci n con la memorizaci n de los par metros en la EEPROM estos par metros en...

Page 34: ...de la tecla din mica normal con la secuencia de Apertura Bloqueo Cierre Bloqueo Pos C Dip 1 ON Dip 2 OFF Cierre autom tico deshabilitado modalidad de funcionamiento de la tecla din mica limitada con l...

Page 35: ...x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x...

Page 36: ...CARACT RISTIQUES TECHNIQUES Stromversorgung V 230 Frequenz Hz 50 Nominalstrom A 1 6 Leistungsaufnahme W 350 Arbeitsintermittenz 25 Getriebegeschwindigkeit dreh min 1 7 Drehmoment Nm 290 Kondensator F...

Reviews: