Gas
system
2999828 - 05/18 - EHG-0012-00EN
55
7
At the operating unit (Fig. 45), the gas supply via the DuoControl regulating
system is switched on and off. The regulator taps (Fig. 43,2) of the gas bot-
tles and the gas isolator taps of the devices must be opened manually.
Summer and winter operation are switched with the rocker switch (Fig. 45,7)
on the operating unit.
The two indicator lamps on the operating unit indicate the level of the pri-
mary bottle. When the green indicator lamp (Fig. 45,6) is lit, the primary bot-
tle is sufficiently filled. When the red indicator lamp (Fig. 45,5) illuminates,
the primary bottle is empty. In this case, the reserve bottle is used for the
gas supply.
Connect the gas bottles.
Use the knob (Fig. 44,1) on the reversing valve to select the gas bottle
which is to be the primary source of gas (primary bottle). Always turn the
knob as far as it will go.
Open regulator taps (Fig. 43,2) on the gas bottles.
Press the green button of the hose break guard (Fig. 43,1). The green
marking is shown in the inspection window (Fig. 44,2).
Switch on the DuoControl regulating system at the operating unit
(Fig. 45). To do so, set the rocker switch (Fig. 45,7) to winter operation
(Fig. 45,2) or to summer operation (Fig. 45,4). The yellow defroster indi-
cator lamp (Fig. 45,1) is lit when winter operation is selected.
Set the rocker switch (Fig. 45,7) to the OFF position (Fig. 45,3). The in-
dicator lamps go out.
Close regulator taps (Fig. 43,2) on the gas bottles.
When changing gas bottles, do not smoke or create any open fire.
When you have changed the gas bottle, check whether gas escapes
at the connection points and unions. Use a leakage search spray to
spray the relevant connection point or union. These agents are
available at the accessories shop.
Connect gas pipe such that it rises from the gas bottle towards the
regulating system (see Fig. 46).
Fig. 46
Correct connection of the gas
bottle
If the green indicator lamp (Fig. 45,6) goes out during operation and the red
indicator lamp (Fig. 45,5) lights up, the primary bottle is empty and must be
changed. The red marking is shown in the inspection window (Fig. 44,2).
The reserve bottle continues supplying the gas appliances with gas.
Operating unit
Putting into operation:
Switching on
summer/winter operation:
Switching off:
Changing gas bottles
Summary of Contents for Sunlight A68 2018
Page 4: ...Contents 4 2999828 05 18 EHG 0012 00EN ...
Page 8: ...Introduction 8 2999828 05 18 EHG 0012 00EN 1 ...
Page 26: ...Before the journey 26 2999828 05 18 EHG 0012 00EN 3 ...
Page 32: ...Pitching the Motorcaravan 32 2999828 05 18 EHG 0012 00EN 5 ...
Page 58: ...Gas system 58 2999828 05 18 EHG 0012 00EN 7 ...
Page 74: ...Electrical system 74 2999828 05 18 EHG 0012 00EN 8 ...
Page 118: ...Wheels and tyres 118 2999828 05 18 EHG 0012 00EN 13 ...
Page 132: ...Helpful notes 132 2999828 05 18 EHG 0012 00EN 15 ...