USING THE BURNERS

The flame symbols printed on the side of the control knobs indicate the 
correspondence between the knob and the flame size on the burner.

TO IGNITE A BURNER:

Turn the corresponding knob anti-clockwise up to the maximum position (large 
flame, fig.1) and press the knob. If you keep the control knob depressed, the 
automatic ignition for the burner will operate.

You should hold down the control knob for 15 seconds after the flame on the 
burner has lit. If after 15 seconds the burner has not lit, stop operating the device 
and open the compartment door and/or wait at least 1 minute before attempting a 
further ignition of the burner.

Burners 

1 Rapid burner
2 Semi-rapid burner 
3 Auxiliary burner 
4 Triple ring burner 

INSTRUCTIONS FOR THE USER

PRODUCT OVERVIEW

1

4

2

3

After this 15-second interval, to regulate the flame you should continue turning 
the control knob anti-clockwise until the flame is at a suitable level. The operating 
position 

MUST

 be at a position between the maximum and minimum position.

To switch the burner off, turn the control knob fully clockwise to the gas off 
position. In case of power failure, the burners can be lit by carefully using a match.

USING THE BURNERS

In order to obtain the maximum yield without 
waste of gas, it is important that the diameter of 
the pan is suitable for the burner potential (see 
the following table) to avoid the flame reaching 
out past the pan (fig. 2).

Burner

Pan Size min.

Pan Size max.

Auxiliary

120mm

140mm

Semi-rapid

160mm

180mm

Rapid

200mm

240mm

Triple ring

200mm

240mm

 
Use the maximum flame to quickly make liquids reach boiling temperature, and 
the reduced flame to heat food or maintain boiling. All of the operating positions 
must be chosen between the maximum and the minimum ones, never between the 
maximum position and ‘off.’

WARNING:

 

- Do not use cookware that overlaps the edge of the burner.

 

- When you are no longer using the hob, always check that the knobs are in the  

off position.

 

- If the flame should blow out accidentally, the safety valve will automatically stop the 

gas supply after a few seconds. To restore operation, set the knob to the lighting 
point and press.

 

- While cooking with fat or oil, pay the utmost attention as these substances can 

catch fire when overheated.

Fig 1

Closed

Minimum

Maximum

Fig 2

Summary of Contents for C749G

Page 1: ...Contact Caple on 0117 938 7420 or for spare parts www caple co uk Gas hob instruction manual C749G ...

Page 2: ...e following actions Do not turn on the light Do not switch any electrical appliances on or off and do not touch any electrical plugs Do not use a telephone Stop using the product and close the middle valve Open windows to ventilate Contact Caple Service and your gas supplier This appliance can be used by children aged from 8 years and above Persons with reduced physical sensory or mental capabilit...

Page 3: ...a plate It must match the mains electrical supply After installation ensure that all electrical components are shielded and cannot be accessed by users The earth cable is not included If the power cable is damaged it must be replaced by the manufacturer by an authorised technician or by a qualified person to avoid danger WARNING This appliance is designed for cooking food and is intended for indoo...

Page 4: ... ensure the hob is not hot Make sure that air circulates around the gas equipment in accordance with regulations in force and only used in a well ventilated space Instruction manual C767G 6 When connecting the power cable make sure it is not in direct contact e g through the use of insulation sleeves with parts that can reach temperatures of over 85 C Do not spray aerosols in the vicinity of this ...

Page 5: ... purchased the product CE DECLARATIONS OF CONFORMITY This appliance has been manufactured to the strictest standards and complies with all applicable legislation Low Voltage Directive LVD Electromagnetic Compatibility EMC and the Gas Appliance Regulation GAR WARRANTY Your new appliance is covered by warranty The warranty card is enclosed if it is missing you must provide the following information ...

Page 6: ...ion MUST be at a position between the maximum and minimum position To switch the burner off turn the control knob fully clockwise to the gas off position In case of power failure the burners can be lit by carefully using a match USING THE BURNERS In order to obtain the maximum yield without waste of gas it is important that the diameter of the pan is suitable for the burner potential see the follo...

Page 7: ...tergents for an extended period of time The stainless steel parts should also be cleaned with soapy water and then dried with a soft cloth WARNING After cleaning the burner make sure that the lid is placed in the housing The 2 reference cuts must be entered on the 2 references made on the flame retardant The burner cap must be positioned steadily and flat BURNERS AND PAN SUPPORTS These parts can b...

Page 8: ...dimensions of the oven in the installation manual The cut out must follow the template 700mm 600mm 400mm 400mm 45mm 25mm MIN 60mm 200mm Min 560mm 490mm If the hob is going to be installed on the top of an oven precautions must be taken to guarantee an installation in accordance with current accident prevention standards Pay particular attention to the position of the electric cable and gas pipe th...

Page 9: ...UNDING IS COMPULSORY This device must be at a suitable opening distance from the contacts in order to allow the entire disconnection in case of over voltage category III in accordance with installation rules GAS ADJUSTMENTS Take precautions on the operations and adjustments to be carried out when converting from one gas to another All work must be carried out by a qualified technician Before you b...

Page 10: ...to use a cable with a section of 3x0 75mm2 type H05VV F or H05RR F complying with the regulations in force The connection to the terminal board must be effected as shown in fig 9 Brown cable Live Blue cable Neutral Green yellow cable Earth GAS SPECIFICATION Model No Gas type pressure Electrical power Heat input and orifice size marked mm Total Heat input Work burner Rapid burner Semi rapid Auxilia...

Page 11: ...adly assembled Assemble the burner lid correctly Flame goes out when in use The flame supervision device is contaminated with an alien substance Clean the flame supervision device Product being cooked has boiled over and extinguished the flame Turn off burner knob Wait one minute and reignite zone A strong draught may have blown the flame out Please turn off zone and check cooking area for draught...

Page 12: ...The appliance has not been serviced maintained repaired taken apart or tampered with by any person not authorised by us All service work under this guarantee must be undertaken by Caple Service Centre Any appliance or defective part replaced shall become the property of this company If a service call is made and it is found that the installation has not been carried out correctly or customer misus...

Page 13: ...Instruction manual C749G Please keep this instruction manual for future reference 24 Caple Service Fourth Way Avonmouth Bristol BS11 8DW t 0117 938 7420 e service caple co uk www caple co uk ...