Caple C749G Instruction Manual Download Page 9

Instruction manual C749G

Instruction manual C749G

Please keep this instruction manual for future reference

Please keep this instruction manual for future reference

16

17

GAS CONNECTION

Make sure that the appliance is adjusted for the gas type available (see the 
label under the appliance). Follow the instructions indicated in the chapter “gas 
transformations and adjustments” for the possible adaptation to different gases.

The appliance must be connected to the gas system by means of stiff metal pipes 
or flexible steel pipes having continuous walls, in compliance with the regulations in 
force. Some models are equipped with both cylindrical A and conical B connectors 
for gas supply (fig. 7 & 8).

Please select the type which is correct for the supply concerned. The connection 
must not stress the gas ramp. Once the installation is over, check the connection 
seal with a soapy solution.

ELECTRIC CONNECTION

The connection to the electric grid must be carried out by qualified personnel and 
in conformity with the regulations in force. The voltage of the electric system must 
correspond to the value indicated in the label under the appliance. Make sure that 
the electric system is provided with an effective ground connection in compliance 
with the regulations and provisions of the law.

GROUNDING IS COMPULSORY

This device must be at a suitable opening distance from the contacts in order to 
allow the entire disconnection in case of over voltage category III, in accordance 
with installation rules.

GAS ADJUSTMENTS

 

- Take precautions on the operations and adjustments to be carried out when 

converting from one gas to another.

 

- All work must be carried out by a qualified technician

 

- Before you begin, turn off the gas and electricity supply to the appliance.

CHANGE THE INJECTOR OF THE BURNERS

 

- Remove the pan support, Burner Lid and Flame Spreader.

 

- Unscrew the injector using a 7mm box spanner and replace it 

with the stipulated injector for new gas supply.

 

- Carefully reassemble all the components.

 

- After injectors are replaced, it is advisable to strongly tighten 

the injector in place.

ADJUSTMENT OF MINIMUM 
LEVEL OF THE FLAME

 

- Turn the taps down to minimum.

 

- Remove the knob from the tap and place a small bladed 

screwdriver in the centre of the tap shaft.

 

- The correct adjustment is obtained when the flame has a 

length of about 3 - 4 mm.

 

- For butane propane gas, the adjusting screw must be tightly 

screwed in.

 

- Refit the control knob.

 

- Make sure that the flame does not go out by quickly turning 

from maximum flow to minimum flow. If it does then remove 
the control knob and make further adjustments to the gas 
flow, testing it again once the adjustment has been made.

 

- Repeat this process for each one of the gas taps.

Fig 7

Fig 8

A

B

Injector

Control 

Handle

Tap

Tap

by-pass 

screw

Sealing 

ring

Summary of Contents for C749G

Page 1: ...Contact Caple on 0117 938 7420 or for spare parts www caple co uk Gas hob instruction manual C749G ...

Page 2: ...e following actions Do not turn on the light Do not switch any electrical appliances on or off and do not touch any electrical plugs Do not use a telephone Stop using the product and close the middle valve Open windows to ventilate Contact Caple Service and your gas supplier This appliance can be used by children aged from 8 years and above Persons with reduced physical sensory or mental capabilit...

Page 3: ...a plate It must match the mains electrical supply After installation ensure that all electrical components are shielded and cannot be accessed by users The earth cable is not included If the power cable is damaged it must be replaced by the manufacturer by an authorised technician or by a qualified person to avoid danger WARNING This appliance is designed for cooking food and is intended for indoo...

Page 4: ... ensure the hob is not hot Make sure that air circulates around the gas equipment in accordance with regulations in force and only used in a well ventilated space Instruction manual C767G 6 When connecting the power cable make sure it is not in direct contact e g through the use of insulation sleeves with parts that can reach temperatures of over 85 C Do not spray aerosols in the vicinity of this ...

Page 5: ... purchased the product CE DECLARATIONS OF CONFORMITY This appliance has been manufactured to the strictest standards and complies with all applicable legislation Low Voltage Directive LVD Electromagnetic Compatibility EMC and the Gas Appliance Regulation GAR WARRANTY Your new appliance is covered by warranty The warranty card is enclosed if it is missing you must provide the following information ...

Page 6: ...ion MUST be at a position between the maximum and minimum position To switch the burner off turn the control knob fully clockwise to the gas off position In case of power failure the burners can be lit by carefully using a match USING THE BURNERS In order to obtain the maximum yield without waste of gas it is important that the diameter of the pan is suitable for the burner potential see the follo...

Page 7: ...tergents for an extended period of time The stainless steel parts should also be cleaned with soapy water and then dried with a soft cloth WARNING After cleaning the burner make sure that the lid is placed in the housing The 2 reference cuts must be entered on the 2 references made on the flame retardant The burner cap must be positioned steadily and flat BURNERS AND PAN SUPPORTS These parts can b...

Page 8: ...dimensions of the oven in the installation manual The cut out must follow the template 700mm 600mm 400mm 400mm 45mm 25mm MIN 60mm 200mm Min 560mm 490mm If the hob is going to be installed on the top of an oven precautions must be taken to guarantee an installation in accordance with current accident prevention standards Pay particular attention to the position of the electric cable and gas pipe th...

Page 9: ...UNDING IS COMPULSORY This device must be at a suitable opening distance from the contacts in order to allow the entire disconnection in case of over voltage category III in accordance with installation rules GAS ADJUSTMENTS Take precautions on the operations and adjustments to be carried out when converting from one gas to another All work must be carried out by a qualified technician Before you b...

Page 10: ...to use a cable with a section of 3x0 75mm2 type H05VV F or H05RR F complying with the regulations in force The connection to the terminal board must be effected as shown in fig 9 Brown cable Live Blue cable Neutral Green yellow cable Earth GAS SPECIFICATION Model No Gas type pressure Electrical power Heat input and orifice size marked mm Total Heat input Work burner Rapid burner Semi rapid Auxilia...

Page 11: ...adly assembled Assemble the burner lid correctly Flame goes out when in use The flame supervision device is contaminated with an alien substance Clean the flame supervision device Product being cooked has boiled over and extinguished the flame Turn off burner knob Wait one minute and reignite zone A strong draught may have blown the flame out Please turn off zone and check cooking area for draught...

Page 12: ...The appliance has not been serviced maintained repaired taken apart or tampered with by any person not authorised by us All service work under this guarantee must be undertaken by Caple Service Centre Any appliance or defective part replaced shall become the property of this company If a service call is made and it is found that the installation has not been carried out correctly or customer misus...

Page 13: ...Instruction manual C749G Please keep this instruction manual for future reference 24 Caple Service Fourth Way Avonmouth Bristol BS11 8DW t 0117 938 7420 e service caple co uk www caple co uk ...

Reviews: