WX6000 / SX6000
User Commands
- 54 -
LMPWRN
Lamp warning indication at startup
Format
LMPWRN=<Lamp warning parameter: ID>
GET
□
LMPWRN / ?
△
LMPWRN
<Lamp warning parameter: ID>
OFF Turned
off
ON Turned
on
Environment
Power
Input
OFF ON
PM
D-RGB A-RGB
COMP
HDMI
None
X O X
-
Response
"i:OK" is returned when setting of lamp warning indication at startup was completed successfully.
For '
GET LMPWRN
' or '
?LMPWRN
', current setting of lamp warning indication at startup is returned as
'g:LMPWRN=<Lamp warning parameter: ID>'
For details on other responses, refer to the "Error List".
Description
(1) This command is used to set the indication of lamp warning at startup.
(2) This command functions in the same way as when "Installation setting" - "On screen" -
"Lamp warning indication" are selected on the menu.
(3) The current setting of lamp warning indication at startup can be obtained using the GET
command. ("
GET LMPWRN
")
(4) The setting of Lamp warning indication at startup retains the last setting after the power is
turned off.
Example
Setting
>
LMPWRN=OFF
Lamp warning indication at startup is disabled.
<
i:OK
Reference
>
GET LMPWRN or ?LMPWRN
The setting of Lamp warning indication at startup is acquired.
<
g:LMPWRN
*Commands are indicated by ">", and responses are indicated by "<".