(8/37)
Error
code
TX /
RX
Meaning
Solution
(parts that are likely to be faulty)
##109 TX
After DCS transmission, a signal other than DIS,
DTC, FTT, CFR, or CRP has been received, and
re-transmission of the procedure signal has been
attempted the specified number of times but failed.
##111 TX /
RX
Memory error
- Eliminate all the data, and register
them again.
##114 RX
RTN has been received.
- Increase the transmission level of the
sending machine.
##200 RX
A carrier has not been detected for 5 seconds
during image reception.
- Increase the transmission level of the
sending machine.
##201 TX /
RX
DCN has been received in a method other than the
binary procedure.
- Set the other machine ready for
reception.
##204 TX
DTC has been received even when there is no
sending data.
##220 TX /
RX
System error (main program hang-up)
- Turn the machine off, and turn it on
again.
- NCU board
##224 TX /
RX
An error has occurred in the procedure signal in G3
transmission.
##226 TX /
RX
The stack pointer has shifted from the RAM area.
- Turn the machine off, and turn it on
again.
##229 RX
The recording area has been locked for 1 minute.
- After the area is unlocked, print the
recorded image.
##232 TX
The encoder control unit has malfunctioned.
- NCU board
##237 RX
The decoder control unit has malfunctioned.
- NCU board
##238 RX
The print control unit has malfunctioned.
- NCU board
- Logic board
##261 TX /
RX
A system error has occurred between the modem
and the system control board.
- NCU board
- Logic board
##280 TX
Re-transmission of the procedure signal has been
attempted the specified number of times, but failed.
- Try a higher transmission level.
##281 TX
Re-transmission of the procedure signal has been
attempted the specified number of times, but failed.
- Try a higher transmission level.
##282 TX
Re-transmission of the procedure signal has been
attempted the specified number of times, but failed.
- Try a higher transmission level.
##283 TX
Re-transmission of the procedure signal has been
attempted the specified number of times, but failed.
- Try a higher transmission level.
##284 TX
After TCF transmission, DCN has been received.
- Set the receiving machine ready for
reception.
##285 TX
After EOP transmission, DCN has been received.
- Re-send the fax.
##286 TX
After EOM transmission, DCN has been received.
- Re-send the fax.
##287 TX
After MPS transmission, DCN has been received.
- Re-send the fax.
##288 TX
After EOP transmission, a signal other than PIN,
PIP, MCF, RTP, RTN has been received.
##289 TX
After EOM transmission, a signal other than PIN,
PIP, MCF, RTP, RTN has been received.
##290 TX
After MPS transmission, a signal other than PIN,
PIP, MCF, RTP, RTN has been received.
Summary of Contents for PIXMA MX340 Series
Page 22: ... 21 37 PTT parameter print sample for the MX350 US model ...
Page 30: ... 29 37 3 5 Grease application ...
Page 32: ... 31 37 4 EXTERNAL VIEW PARTS LIST 4 1 External View Fig 1 ...
Page 33: ... 32 37 Fig 2 1 For the MX340 MX347 MX348 only 2 For the MX350 MX357 MX358 only ...
Page 34: ... 33 37 Fig 3 ...
Page 35: ... 34 37 Fig 4 2 For the MX350 only 3 Ink absorbers to be replaced in the partial replacement ...