<Service report output>
The service data setting status, communication report, and error information report can be output via the service data settings.
1) Reports for service use
<How to set SSSW>
1) In the user mode, press and hold the Stop/Reset button until the Alarm LED blinks 12 times in orange, then release the
button.
2) "SERVICE MODE #1 BIT SWITCH" is displayed on the LCD to indicate the machine is in the SSSW mode.
3) Press the OK button. "SW#01 00000000" will additionally be displayed on the LCD.
4) Using the right or left cursor button, set bit 2 (the rightmost digit (LSB)) and bit 1 (the second digit from the right) to "1."
5) Press the OK button.
6) Press the Stop/Reset button.
7) Press the ON/OFF button to turn off the machine.
Report
Operation
System data list
In the user mode, press and hold the Stop/Reset button until the
Alarm LED blinks 13 times in orange, then release the button.
Error TX report (with service error code and dump
list)
In service data #1 SSSW SW01, set bit 0 and bit 1 to "1." The
service error code and dump list will be added to the transmission
report. For details, see <How to set SSSW> below.
Error RX report (with service error code and dump
list)
In service data #1 SSSW SW01, set bit 0 and bit 1 to "1." The
service error code and dump list will be added to the reception
report. For details, see <How to set SSSW> below.
1-50
Summary of Contents for PIXMA MP530
Page 5: ...Part 1 MAINTENANCE ...
Page 34: ... Right side c Disconnect the connector for the solenoid 1 29 ...
Page 51: ... Service test print sample 1 46 ...
Page 56: ... System data list sample 1 51 ...
Page 57: ... Error transmission report sample 1 52 ...
Page 60: ...Part 2 TECHNICAL REFERENCE ...
Page 73: ...Part 3 APPENDIX ...