4–7
TROUBLESHOOTING MALFUNCTIONS
Cause
Connector
(displaced),
Harness
(open
circuit)
Power
supply
cooling fan
Composite
power
supply PCB
DC
controller
PCB
Checks
Is there a diaplaced connector or open
circuit between the power supply
cooling fan (FM3) in the composite
power supply unit and the DC
controller PCB?
Replace the power supply cooling fan.
Is the problem corrected?
Replace the composite power supply
PCB. Is the problem corrected?
Yes/No
YES
YES
YES
NO
Remedy
Connect the connector or
replace the harness.
End.
End.
Replace the DC controller
PCB.
Step
1
2
3
11
E260
Cause
Power
supply
frequency
(fluctuation)
Composite
power
supply PCB
DC control-
ler PCB
Checks
Turn OFF/ON the power. Is the
problem corrected?
Replace the composite power supply
PCB. Is the problem corrected?
Yes/No
YES
YES
NO
Remedy
End.
• However, if the problem is
frequent, advise the user to
provide a frequency safety
device.
End.
Replace the DC controller
PCB.
Step
1
2
12
E261