![Canon NP6621 Service Handbook Download Page 37](http://html.mh-extra.com/html/canon/np6621/np6621_service-handbook_59710037.webp)
2–23
STANDARDS AND ADJUSTMENTS
Notation
Name
(+) probe of meter
Service mode
Checks; normal if as
indicated.
Display
Meter measurements
PS6
Registration sensor (RPD)
J316-13
No. 222
1-a
Open the right door while in
standby, and insert copy paper
between the paper guide plates.
PS5
Multifeeder paper sensor (MFPD*)
J316-10
No. 221
1-a
Set paper on the multifeeder tray
while in standby.
When paper is
set
0
—
When paper is
not set
1
—
When paper is
inserted
1
5 V (approx.)
When paper is
not inserted
0
0 V (approx.)
Notation
Name
(+) probe of meter
Service mode
Checks; normal if as
indicated.
Display
Meter measurements
PS8
Delivery sensor (DPD*)
J309-14
No. 221
1-b
Operate the detection lever with a
finger while in standby.
PS7
Separation sensor (SPD*)
J316-4
No. 221
1-d
Operate the detection lever with a
finger while in standby.
When the lever
is operated
0
—
When the lever
is not operated
1
—
When the lever
is operated
0
5V (approx.)
When the lever
is not operated
1
0V (approx.)
Summary of Contents for NP6621
Page 4: ...ii ...
Page 8: ...vi ...
Page 48: ...3 2 IMAGE FAULTS ...
Page 49: ...3 3 IMAGE FAULTS NOT USED ...
Page 50: ...3 4 IMAGE FAULTS B Image Fault Samples not available ...
Page 80: ...4 16 TROUBLESHOOTING MALFUNCTIONS ...
Page 134: ...A 4 APPENDIX ...
Page 135: ...A 5 APPENDIX C GENERAL CIRCUIT DIAGRAM not available ...
Page 136: ...A 6 APPENDIX ...
Page 144: ...A 14 APPENDIX ...