4–13
TROUBLESHOOTING MALFUNCTIONS
Cause
Registration
roller
DC control-
ler PCB
CL1 (regis-
tration
clutch)
Step
1
2
Checks
Press the Copy Start key. Does the
registration roller rotate for about 1 sec
immediately after the scanner starts to
move forward?
Set the meter to the 30 VDC range.
does the voltage between J312A-5 (+)
and J312A-6 (–) on the DC controller
PCB change from about 0 V to about
24 V?
Remedy
Check the drive assembly of
the registration roller.
Replace the DC controller
PCB.
Check the wiring from the
DC controller PCB to CL1; if
normal, replace CL1.
22
The registration roller fails to operate.
Yes/No
YES
NO
YES
Cause
Scanning
lamp
Scanning
lamp
Dc controller
PCB
Composite
power
supply PCB
Step
1
2
3
Checks
Turn OFF the power switch, and
disconnect the power plug. Is the lamp
installed correctly?
Have the ends of the scanning lamp
blackened?
Replace the DC controller PCB. Is the
problem corrected?
Remedy
Re-install the lamp.
Replace the scanning lamp.
Replace the DC controller
PCB.
Check the wiring from the
DC controller PCB and the
composite power supply
PCB; if normal, replace the
composite power supply
PCB.
Yes/No
NO
YES
YES
NO
23
The scanning lamp fails to turn ON.
Summary of Contents for NP6621
Page 4: ...ii ...
Page 8: ...vi ...
Page 48: ...3 2 IMAGE FAULTS ...
Page 49: ...3 3 IMAGE FAULTS NOT USED ...
Page 50: ...3 4 IMAGE FAULTS B Image Fault Samples not available ...
Page 80: ...4 16 TROUBLESHOOTING MALFUNCTIONS ...
Page 134: ...A 4 APPENDIX ...
Page 135: ...A 5 APPENDIX C GENERAL CIRCUIT DIAGRAM not available ...
Page 136: ...A 6 APPENDIX ...
Page 144: ...A 14 APPENDIX ...