2–25
STANDARDS AND ADJUSTMENTS
Notation
Name
(+) probe of meter
Service mode
Checks; normal if as
indicated.
Display
Meter measurements
PS14
Duplexing unit outlet paper sensor
(DUEX)
J325-2
—
Open the duplexing unit, and push
the flag of the sensor by a finger.
When the flag is
pushed
1
5V
When the flag is
not pushed
0
0V
PS16
Vertical path roller 1 paper sensor
(VP1P)
J314-13
—
Open the right door, and push the
sensor flag.
PS15
Duplexing unit paper outlet sensor
(DUIN)
J320-2
—
Open the duplexing unit, and press
the flag of the sensor.
When the sensor
is pushed
1
5V
When the sensor
is not pushed
0
0V
When the flag is
pushed
1
5V
When the flag is
not pushed
0
0V
Notation
Name
(+) probe of meter
Service mode
Checks; normal if as
indicated.
Display
Meter measurements