COPYRIGHT © 1996 CANON INC.
CANON NP6085 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
•
LMP1 and LMP2 indicate the ON control voltage value even when the scanning lamp is OFF.
Caution: You must execute ‘wire cleaning’ in user mode (
mode) if a number other than ‘0 is indicated
under ‘WIRE’ because of an error in the charging wire cleaner.
If the wire cleaning motor and the wire cleaning assembly are normal, executing ‘wire cleaning’
will operate the cleaner unit; as a result, it will stop at home position and the indication will
change to ‘0’.
(Wire cleaning will be prohibited unless you execute ‘wire cleaning’. This state will remain even
when the power switch is turned OFF/ON.)
table 3-1002
✻
3. OPERATIONS AND TIMING
3-184
Indication
Charging assembly with an error
in the cleaner
0 Normal
end
1
Primary charging assembly
2
Pre-transfer charging assembly
3
Primary charging assembly,
pre-transfer assembly
4 Transfer/separation
charging
assembly
5
Primary charging assembly,
transfer/separation charging
assembly
6
Pre-transfer charging assembly,
transfer/separation charging
assembly
7
Primary charging assembly,
pre-transfer charging assembly,
transfer/separation charging
assembly