COPYRIGHT © 1996 CANON INC.
CANON NP6085 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
3. OPERATIONS AND TIMING
3-227
G. Function Mode (
)
•
Press the
/
key to select the appropriate screen.
•
Press the item to select. (The selected item will be highlighted.)
•
Press the
key to start the function.
•
Be sure to execute each item in standby state.
•
In this mode, the Copy Start key will be disabled.
Screen 4-1
OK
✻
4
✻
DISP_LED : 0 (1:EXECUTING)
BLANK : 0 (1:EXECUTING)
PRE_EXP : 0 (1:EXECUTING)
SCANLAMP : 0 (1:EXECUTING)
LCD_CHK : 0 (1:EXECUTING)
✻
4
✻
FUNCTION
OK
Item
Description
Remarks
Use it to check if the indications on
the control panel turn ON.
Use it to check if the blank exposure
LED turns ON.
Use it to check if the pre-exposure
LED turns ON.
Use it to check if the scanning lamp
turns ON.
Use it to turn ON the LCD (all ON).
DISP_LED
BLANK
PRE_EXP
SCANLAMP
LCD_CHK
A press on the
key will keep the LEDs
on the control panel ON for 3 sec. (all ON)
A press on the
key will keep the blank
exposure LED ON for 5 sec. (all ON)
A press on the
key will keep the pre-
exposure LED ON for 5 sec. (all ON)
A press on the
key will keep the scan-
ning lamp ON for 3 sec.
A press on the
key will turn the entire
LCD white for 3 sec, blue for 1 sec, and back
to normal.
OK
OK
OK
OK
OK