Computer Input
39
Computer Input
Aspect Setting
(For LV-8225)
This projector has the picture screen resize function, which enables you to customize the image size.
Aspect Menu
Provide the image to fit the screen size.
Normal
True
Provide the image in its original size. When the
original image size is larger or smaller than the
screen size (180 x 800), the projector enters to the
panning mode automatically. Use the Point ▲▼◄►
buttons to pan the image. When adjusted, the arrows
will turn red. When reached to the correction limits,
the arrows will disappear.
Full
Provide the full screen image.
Note:
• This projector cannot display any resolution
higher than 190 x 100. If your computer’s
screen resolution is higher than it, reset the
resolution to the lower before connecting to
the projector.
• The image data in other than 180x800 is
modified to fit the screen size in initial mode.
•
16:9
,
True
and
Digital zoom +/–
are
disabled and cannot be displayed when
480i
,
575i
,
480p
,
575p,
720p
,
1035i
or
1080i
is
selected in the PC System Menu (p.31).
• When
True
is selected in the Screen menu,
Digital zoom +/-
can not be selected.
1
2
Press the MENU button to display the On-Screen
Menu. Use the Point ▲▼ buttons to select
Screen
and then press the Point
►
or the OK
button.
Use the Point ▲▼ buttons select the desired
item and then press the OK button .
Custom
Provide the last stored aspect screen image.
16:9
Provide the image at the 16:9 wide screen ratio.
Adjust the screen scale and position manually with
this function. Press the Point
►
button at
Custom
adj
.
and the Custom adjustment menu is displayed on the
screen, you can use the Point ▲▼ buttons to choose
the item you want to adjust.
Scale H/V
.......... Adjust the Horizontal/Vertical
screen scale.
H&V
................... When set to
On
, the aspect ratio
is fixed. The
Scale V
appears
dimmed and becomes unavailable.
Adjust
Scale H
, then the screen
scale is automatically modified
based on the aspect ratio.
Position H/V
..... Adjust the Horizontal/Vertical
screen position.
Common
........... Save the adjusted scale or position
to all the inputs. Press the OK
button at
Common
to display a
confirmation box. To save the scale
or position, press the OK button at
“Yes”. When
Custom
is selected,
the saved scale or position is used.
Reset
................. Reset the all adjusted values.
Press the OK button at
Reset
to
display a confirmation box. To
reset, press the OK button at “Yes”.
Custom adj.
Note:
• When no signal is detected,
Normal
is set
automatically .
• The adjustable range for
Scale H/V
and
Position H/V
is limited depending on the
input signal.
Zoom
Scale the image proportionally to fit the entire screen.
Either side of image may go over the screen.
Custom adj.