Parts Replacement/Cleaning Procedure > Consumale Parts Requiring Periodic Replacement and Cleaning Points > Removing the Inserter torque limiter (upper)
Parts Replacement/Cleaning Procedure > Consumale Parts Requiring Periodic Replacement and Cleaning Points > Removing the Inserter torque limiter (upper)
Removing the Inserter feed roller (lower)
1) Remove the rear cover.
2) Increase the top cover open/
close angle.
3) Increase the middle guide
open/close angle.
4-10)
4) Remove six screws to remove the rear transfer
guide.
x6
5) Remove one spring, two resin E-rings, and two
earings to remove the pickup roller unit.
6) Remove three E-rings, one pickup roller, and one lever to
remove the i
nserter feed roller (lower).
Removing the Inserter torque limiter (upper)
1) Remove the rear cover.
2) Increase the top cover open/
close angle.
3) Remove five screws to remove the transfer guide.
x5
4) Remove three E-rings, one gear, one parallel pin, two bearings,
and one separation roller to remove the
inserter torque limiter
(upper).