CHAPTER 2 STANDARDS AND ADJUSTMENTS
2-15
3.2 Routing the Charging Wire of Charging Assemblies
3.2.1 Routing the Charging Wire
All charging wires (except the grid wire) are routed more or less in the same way; the fol-
lowing cites the primary charging assembly:
1) Remove the shielding plate (left, right)
of the charging assembly. To prevent
deformation (slack) in the primary
charging assembly, be sure to work
separately for the left shielding plate
and the right shielding plate (i.e., do not
loosen the mounting screws [1] of both
shielding plates at the same time).
2) Remove the wire cleaner.
F02-203-04
For other charging assemblies,
remove the two lids.
[1]