CHAPTER 2 STANDARDS AND ADJUSTMENTS
2-13
3. Image Formation System
3.1 Routing the Grid Wire of the Primary Charging Assembly
1) Loosen the two mounting screws used
to secure the left and right shielding
plates in place.
2) Loosen the three mounting screws used
to secure the motor unit in place at the
front.
F02-203-01
3) Loosen the mounting screw, and move
it in the direction indicated; then, fix it
in place temporarily.
4) Free a length of about 5 cm of charging
wire from the charging wire reel (0.1
mm in diameter), and form a loop at its
end with a diameter of about 2 mm.
F02-203-02
REF.
To form a loop, wind the charg-
ing wire around a hex key once,
and turn the hex key three to
four times; then, twist the charg-
ing wire.
Screws
Screw