Chapter 14
14-7
14.4 Finisher Error Codes
14.4.1 Error Code Details
0017-6043
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
T-14-8
Display
code
Detail
Code
Main Cause/Symptom
Countermeasure
E500
0001
Finisher communication error
Data communication could not be performed
normally. It has been retried three times in vain.
- Check the connectors of the finisher controller PCB and DC controller PCB for
normal connection.
- Replace the finisher controller PCB.
- Replace the DC controller PCB.
E520
0001
- Offset motor or finisher controller PCB failure
- Offset HP sensor failure
- The offset motor was driven for 1000 ms in the
HP sensor approach direction, but the offset HP
sensor did not turn on.
- Check the connector of the offset HP sensor.
- Check the connector of the offset motor.
- Replace the offset HP sensor.
- Replace the offset motor.
- Replace the finisher controller PCB.
0002
- Offset motor or finisher controller PCB failure
- Offset HP sensor failure
- The offset motor was driven for 1000 ms in the
HP sensor escape direction, but the offset HP
sensor did not turn off.
- Check the connector of the offset HP sensor.
- Check the connector of the offset motor.
- Replace the offset HP sensor.
- Replace the offset motor.
- Replace the finisher controller PCB.
E531
0001
- Staple unit failure
- Staple HP sensor failure
- Finisher controller PCB failure
- The staple home position was not left when 400
ms have lapsed since start of staple operation.
- Check the connector of the staple unit.
- Replace the staple unit.
- Replace the finisher controller PCB.
0002
- Staple unit failure
- Staple HP sensor failure
- Finisher controller PCB failure
- The staple home position had been left once, but
it was not reached again when 400 ms have lapsed
since start of staple operation. In addition, the
staple home position could not be reached by
performing reverse operation for 400 ms.
- Check the connector of the staple unit.
- Replace the staple unit.
- Replace the finisher controller PCB.
Summary of Contents for iR2030
Page 1: ...Aug 8 2007 Service Manual iR2030 2025 2022 2018 Series ...
Page 2: ......
Page 6: ......
Page 20: ...Contents ...
Page 21: ...Chapter 1 Introduction ...
Page 22: ......
Page 57: ...Chapter 1 1 33 ...
Page 60: ......
Page 61: ...T 1 11 ...
Page 64: ......
Page 65: ...T 1 12 ...
Page 68: ......
Page 69: ...Chapter 2 Installation ...
Page 70: ......
Page 72: ......
Page 125: ...Chapter 2 2 53 ...
Page 126: ......
Page 127: ...Chapter 3 Main Controller ...
Page 128: ......
Page 130: ......
Page 142: ......
Page 143: ...Chapter 4 Original Exposure System ...
Page 144: ......
Page 170: ......
Page 171: ...Chapter 5 Laser Exposure ...
Page 172: ......
Page 174: ......
Page 181: ...Chapter 6 Image Formation ...
Page 182: ......
Page 184: ......
Page 196: ......
Page 197: ...Chapter 7 Pickup Feeding System ...
Page 198: ......
Page 217: ...Chapter 8 Fixing System ...
Page 218: ......
Page 220: ......
Page 234: ......
Page 235: ...Chapter 9 External and Controls ...
Page 236: ......
Page 255: ...Chapter 10 RDS ...
Page 256: ......
Page 258: ......
Page 268: ......
Page 269: ...Chapter 11 Maintenance and Inspection ...
Page 270: ......
Page 272: ......
Page 275: ...Chapter 12 Standards and Adjustments ...
Page 276: ......
Page 278: ......
Page 281: ...Chapter 12 12 3 ...
Page 282: ......
Page 283: ...Chapter 13 Correcting Faulty Images ...
Page 284: ......
Page 286: ......
Page 299: ...F 13 11 F 13 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 ...
Page 300: ......
Page 301: ...Chapter 14 Self Diagnosis ...
Page 302: ......
Page 304: ......
Page 317: ...Chapter 15 Service Mode ...
Page 318: ......
Page 381: ...Chapter 16 Upgrading ...
Page 382: ......
Page 384: ......
Page 411: ...Chapter 17 Service Tools ...
Page 412: ......
Page 414: ......
Page 417: ...Aug 8 2007 ...
Page 418: ......