COPYRIGHT © 2002 CANON INC.
2000 2000 2000 2000
CANON iR1200/iR1300 Series REV. 0 AUG. 2002
CHAPTER 5 MECHANICAL SYSTEM
5-58
6) Free the harness [7] from the harness
guide [8], and detach the fixing film unit
[9].
7) Remove the fixing pressure roller [10].
[9]
[10]
[8]
[7]
[8]
F05-207-07
2.7.3 Removing the Delivery Sensor
1) Remove the fixing assembly. (See 2.7.1)
2) Disconnect the connector [1].
3) Free the 2 hooks [2], and detach the de-
livery sensor [3].
[1]
[3]
[2]
F05-207-08