CHAPTER 5 MECHANICAL SYSTEM
5-54
2.6.9 Removing the Registration Roller Unit
1) Remove the image processor PCB. (See
2.2.1)
2) Using long nose pliers or the like, pick
the hook [1], and detach the registration
roller gear [2].
When removing the gear,
be sure to take care not to
break the claw.
[1]
[2]
F05-206-21
3) Slide the reader unit, and open the car-
tridge cover.
4) Remove the 6 screws [3], and detach the
registration roller unit [4].
[4]
[3]
[3]