COPYRIGHT © 2002 CANON INC.
2000 2000 2000 2000
CANON iR1200/iR1300 Series REV. 0 AUG. 2002
7-71
CHAPTER 7 TROUBLESHOOTING
##288 [TX]
After transmitting EOP, a signal other than PIN, PIP, MCF, RTP, or
RTN was received
The procedure signal has a fault.
Record the protocol on a DAT or MD, and have it analyzed by the local Canon
office and/or Technical Center.
Cause:
Remedy:
##289 [TX]
After transmitting EOM, a signal other than PIN, PIP, MCF, RTP, or
RTN was received
The procedure signal has a fault.
Record the protocol on a DAT or MD, and have it analyzed by the local Canon
office and/or Technical Center.
##290 [TX]
After transmitting MPS, a signal other than PIN, PIP, MCF, RTP, or
RTN was received
The procedure signal has a fault.
Record the protocol on a DAT or MD, and have it analyzed by the local Canon
office and/or Technical Center.
Cause:
Remedy:
Cause:
Remedy:
##671 [RX]
In V.8 call arrives, the procedure fails to advance to phase 2 after
CM detection, causing a T1 time-over condition
In phase 1, the other party cannot receive the signal correctly and disconnect the
line.
(1) Increase the transmission level so that the other party may receive the signal
correctly.
(2) Prohibit the V.8/V.34 procedure.
In phase 1, the signal from the other party cannot be received correctly.
(1) Ask the operator of the other party to increase the transmission level so that
the signal may be received correctly.
(2) Prohibit the V.8/V.34 procedure.
Cause:
Remedy:
Cause:
Remedy:
##670 [TX]
In V.8 late start, the V.8 ability was detected in DIS from the other
party and, in response, CI was transmitted; however, the procedure
failed to advance, causing a T1 time-over condition
CI was transmitted, but the other party failed to receive it correctly and disconnect
the line.
(1) Increase the transmission level so that the other party may receive CI cor-
rectly.
(2) Prohibit the V.8/V.34 procedure.
ANSam or DIS from the other party cannot be received correctly.
(1) Ask the operator of the other party to increase the transmission level so that
the signal may be received correctly.
(2) Prohibit the V.8/V.34 procedure.
Cause:
Remedy:
Cause:
Remedy: