Service Mode > COPIER > DISPLAY > HV-STS
Service Mode > COPIER > DISPLAY > HV-STS
COPIER> DISPLAY> HV-STS
1ATVC-C
Dspl of primary transfer current (C)
Details
To display the decuple value of the current flown to the Primary Transfer
Roller (C) by the primary transfer ATVC control.
When the two values are out of the target value range (50 to 700), clear
the log information for the appropriate control (COPIER> FUNCTION>
CLEAR> 1TR-CLR).
If the two values are both small, the Primary Transfer Roller may have
reached the end of life.
Use case
When estimating the life of Primary Transfer Roller based on the
displayed value
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 900
Unit
1 uA
Appropriate target value 50 - 700
Related service mode
COPIER> FUNCTION> CLEAR> 1TR-CLR
1ATVC-C2
Dspl of primary transfer current (C)
Details
To display the decuple value of the current flown to the Primary Transfer
Roller (C) by the primary transfer ATVC control.
When the two values are out of the target value range (50 to 700), clear
the log information for the appropriate control (COPIER> FUNCTION>
CLEAR> 1TR-CLR).
If the two values are both small, the Primary Transfer Roller may have
reached the end of life.
Use case
When estimating the life of Primary Transfer Roller based on the
displayed value
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 900
Unit
1 uA
Appropriate target value 50 - 700
Related service mode
COPIER> FUNCTION> CLEAR> 1TR-CLR
1ATVC-C3
Dspl of primary transfer current (C)
Details
To display the decuple value of the current flown to the Primary Transfer
Roller (C) by the primary transfer ATVC control.
When the two values are out of the target value range (50 to 700), clear
the log information for the appropriate control (COPIER> FUNCTION>
CLEAR> 1TR-CLR).
If the two values are both small, the Primary Transfer Roller may have
reached the end of life.
Use case
When estimating the life of Primary Transfer Roller based on the
displayed value
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 900
Unit
1 uA
Appropriate target value 50 - 700
Related service mode
COPIER> FUNCTION> CLEAR> 1TR-CLR
COPIER> DISPLAY> HV-STS
1ATVC-K4
Dspl prmry trns current(Bk):full clr mod
Details
To display the decuple value of the current flown to the Primary Transfer
Roller (Bk) by the primary transfer ATVC control in full color mode.
When the two values are out of the target value range (50 to 700), clear
the log information for the appropriate control (COPIER> FUNCTION>
CLEAR> 1TR-CLR).
If the two values are both small, the Primary Transfer Roller may have
reached the end of life.
Use case
When estimating the life of Primary Transfer Roller based on the
displayed value
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 900
Unit
1 uA
Appropriate target value 50 - 700
Related service mode
COPIER> FUNCTION> CLEAR> 1TR-CLR
1ATVC-K42
Dspl prmry trns current(Bk):full clr mod
Details
To display the decuple value of the current flown to the Primary Transfer
Roller (Bk) by the primary transfer ATVC control in full color mode.
When the two values are out of the target value range (50 to 700), clear
the log information for the appropriate control (COPIER> FUNCTION>
CLEAR> 1TR-CLR).
If the two values are both small, the Primary Transfer Roller may have
reached the end of life.
Use case
When estimating the life of Primary Transfer Roller based on the
displayed value
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 900
Unit
1 uA
Appropriate target value 50 - 700
Related service mode
COPIER> FUNCTION> CLEAR> 1TR-CLR
1ATVC-K43
Dspl prmry trns current(Bk):full clr mod
Details
To display the decuple value of the current flown to the Primary Transfer
Roller (Bk) by the primary transfer ATVC control in full color mode.
When the two values are out of the target value range (50 to 700), clear
the log information for the appropriate control (COPIER> FUNCTION>
CLEAR> 1TR-CLR).
If the two values are both small, the Primary Transfer Roller may have
reached the end of life.
Use case
When estimating the life of Primary Transfer Roller based on the
displayed value
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 900
Unit
1 uA
Appropriate target value 50 - 700
Related service mode
COPIER> FUNCTION> CLEAR> 1TR-CLR
Summary of Contents for imageRUNNER C1335 Series
Page 14: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Page 372: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Page 440: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Page 600: ... Service Tools General Circuit Diagram Backup Data Soft counter specifications Appendix ...