3) Network settings
Based on the results of the information obtained in 2) Advance preparations, make this
machine network related settings.
See Users’ Guide for detailed procedures.
CAUTION:
When changes are made to the above-mentioned network settings, be sure to turn OFF
and then ON the main power of this machine.
■
Steps to E-RDS settings
1) Start [Service Mode].
2) Select [COPIER] > [FUNCTION] > [CLEAR] > [ERDS-DAT] and press the [Start] key.
NOTE:
This operation initializes the E-RDS settings to factory setting values.
For the setting values to be initialized, see the section of "Initializing E-RDS settings".
3) Select [COPIER] > [FUNCTION] > [INSTALL] > [ERDS].
4) Press the numeric key [1] on the control panel (the setting value is changed to 1) and press
the [Start] key. (The data is reflected to the setting value field.)
NOTE:
This operation enables the communication function with UGW.
CAUTION:
The settings of RGW-PORT in Service mode must not be change unless there are
specific instructions to do so.
Changing these values will cause error in communication with UGW.
5) Select [COM-TEST].
NOTE:
This initiates the communication test between the device and the UGW.
6) Select [COM-RSLT].
If the communication is successful, "OK!" is displayed. If "NG!" (failed) appears, refer to the
"Troubleshooting" and repeat until "OK!" is displayed.
NOTE:
The communication results with UGW can be distinguished by referring to the COM-
LOG. By performing the communication test with UGW, E-RDS acquires schedule
information and starts monitoring and meter reads operation.
■
Initializing E-RDS settings
It is possible to clear the FLASH data of E-RDS and change the E-RDS setting back to the
default value.
●
Initialization procedure
1) Start [Service Mode].
2) Select [COPIER] > [FUNCTION] > [CLEAR] > [ERDS-DAT] and press the [Start] key.
●
Setting values and data to be initialized
The following E-RDS settings, internal data, and Alarm filtering information are initialized.
• COPIER > FUNCTION > INSTALL > ERDS
• COPIER > FUNCTION > INSTALL > RGW-PORT
• COPIER > FUNCTION > INSTALL > COM-LOG
Summary of Contents for imageRUNNER C1335 Series
Page 14: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name ...
Page 372: ...7 7 Error Jam Alarm Error Jam Alarm Overview Error Code Jam Code Alarm Code ...
Page 440: ...8 8 Service Mode Service Mode Overview COPIER FEEDER FAX TESTMODE ...
Page 600: ... Service Tools General Circuit Diagram Backup Data Soft counter specifications Appendix ...