NOTE:
• Obtain network environment information from the system administrator.
• When the network settings are changed, "Apply Settings" is displayed on the screen.
● Preparations When Using a Sub Line
Certain equipment is required when using E-RDS with the use of a sub line.
Equipment required for the sub line use
If connecting via wireless LAN (sub line):
• Wireless LAN router
If connecting via wired LAN (sub line):
• USB-LAN adapter
CAUTION:
Firmware is pre-installed with the USB-LAN adapter driver, which accepts USB-LAN adapters by certain manufacturers
only.
For details on mobile routers and USB-LAN adapters to use (e.g. manufacturers, purchasing), follow instructions from your
sales company.
■ Procedure for Setting E-RDS
1. Log in as an administrator.
2. Make sure E-RDS is enabled. If it is disabled, enable it.
COPIER > Function > INSTALL > E-RDS
3. Choose a connection line.
Counter Key > Monitoring Service > Send Method
Only the system administrator can set the connection line selection.
4. Perform a communication test with Remote Monitoring Server.
Counter Key > Monitoring Service > Communication Test > Start Test
CAUTION:
When the service mode below is "1", the communication test (COM-TEST) fails with an error (0x840f0003).
If the RMS-SW is "1", change to "0" and turn OFF/ON the main power before setting the E-RDS.
COPIER > OPTION > DSPLY-SW > RMS-SW
NOTE:
You can also perform a communication test through COM-TEST in service mode.
COM-LOG shows the status of communication with Remote Monitoring Server. Performing a communication test with Remote
Monitoring Server allows E-RDS to retrieve scheduled delivery data and start monitoring.
Error Message List
Error information displayed on the communication error log detail screen is shown below.
(The "server" described here means Remote Monitoring Server.)
• Error information is displayed in the format shown below.
[*] [character strings]: [function classification (the method name, etc.)] [detailed error information on the server side]
NOTE:
"*" is added to the beginning of the error character strings only in the case of an error in a communication test (method name:
"getConfiguration" or "communicationTest").
8. Monitoring Function